Skip to content

GDU Calculator: Growing Degree Days for Corn and Other Crops

Growing degree days for corn, soybean, wheat or any base temperature, day by day and accumulated, with the 86 °F cap.

Your details

Unit system
Method
Daily temperatures in
Daily maximum and minimum

One row per day; a single row gives one day’s GDU. Paste a season from your weather station or a public weather record.

GDU required for a stage, on the same scale as your temperatures — e.g. a hybrid’s GDU to black layer from the seed catalogue.

Results update as you type

Growing degree days

104 °F·d

In Celsius degree days
57.8 °C·d
Days
5
Average per day
20.8

Step-by-step solution
  1. Day 1: (86 + 62) ÷ 2 − 50 = 24
  2. Σ 5 = 104

Crops do not follow the calendar; they follow heat. A cool May can delay corn emergence by a week while a hot June races it toward tasseling. Growing degree days (GDD) — called growing degree units (GDU) or heat units in the corn belt — measure that heat: each day contributes how far its average temperature rises above a base temperature below which the crop does not develop.

This GDU calculator takes daily maximum and minimum temperatures, one day or a whole season, and returns the daily and accumulated total with a table and a chart. Presets cover corn and soybean (base 50 °F / 10 °C with an 86 °F / 30 °C upper cap, the "modified" method used by Purdue and Iowa State) and wheat or barley (base 32 °F / 0 °C), or you can enter any base and cap for vegetables, fruit trees or insects.

Add an optional target — for instance the GDU to black layer printed in a seed catalogue — and the calculator shows how much heat is still needed and how many days that represents at the current pace. Purdue’s Bob Nielsen notes that central Indiana accumulates roughly 10 GDD a day in late April, 23 a day in late July and about 2,800 over a full season.

How to use this calculator

  1. Choose the crop to load its thresholds, or Custom to set your own base and optional upper cap.
  2. Pick the method: modified (temperatures clamped between base and cap — standard for corn) or simple average.
  3. Choose whether your readings are in °F or °C.
  4. Enter one row per day with the maximum and minimum temperature.
  5. Optionally enter a target in the same scale.
  6. Read the total, the per-day table and the accumulation chart.

The formula

Simple method (McMaster and Wilhelm’s method 1):

GDD=max⁡(0,  Tmax⁡+Tmin⁡2−Tbase)\text{GDD} = \max\left(0,\; \frac{T_{\max} + T_{\min}}{2} - T_{\text{base}}\right)

Modified method (method 2, corn GDU): each temperature is first limited to the range [Tbase,Tupper][T_{\text{base}}, T_{\text{upper}}]:

T′=min⁡(Tupper,max⁡(Tbase,T))GDU=Tmax⁡′+Tmin⁡′2−TbaseT' = \min(T_{\text{upper}}, \max(T_{\text{base}}, T)) \qquad \text{GDU} = \frac{T'_{\max} + T'_{\min}}{2} - T_{\text{base}}

For corn, Tbase=50T_{\text{base}} = 50 °F and Tupper=86T_{\text{upper}} = 86 °F (10 and 30 °C). The season total is the sum of daily values. A Fahrenheit degree day is 1.8 times a Celsius degree day, so GDD°F=1.8×GDD°C\text{GDD}_{°F} = 1.8 \times \text{GDD}_{°C}.

Worked example

Five summer days for corn, in °F: 86/62, 90/65, 78/55, 70/48 and 95/70.

  • Day 1: (86+62)/2−50=24(86 + 62)/2 - 50 = 24
  • Day 2: the 90 °F maximum is capped at 86, so (86+65)/2−50=25.5(86 + 65)/2 - 50 = 25.5
  • Day 4: the 48 °F minimum is raised to 50, so (70+50)/2−50=10(70 + 50)/2 - 50 = 10
  • Day 5: (86+70)/2−50=28(86 + 70)/2 - 50 = 28

The five days total 104 GDU (57.8 in °C). The simple method, without the caps, would give 109.5, overstating the heat the crop could actually use.

Base temperatures for common crops

Crop Base Upper cap
Corn, sweet corn, sorghum 50 °F (10 °C) 86 °F (30 °C)
Soybean 50 °F (10 °C) 86 °F (30 °C) in most tools
Wheat, barley, oats 32 °F (0 °C) usually none
Canola, peas about 41 °F (5 °C) —
Many insect pests 48–52 °F (9–11 °C) species-specific

The base and cap depend on the crop and the model a guide was built on, so use the thresholds of the reference you compare against — a corn hybrid rating in GDU assumes the 50/86 °F modified method.

Using GDU to plan the season

Seed companies rate corn hybrids by the GDU needed from planting to silking and to black layer (physiological maturity). Summing GDU from your planting date tells you how far along a field is and whether a late-planted hybrid will mature before the first frost. The same idea times herbicide windows, scouting for insects whose development is also driven by heat, or harvest of peas and sweet corn for processing. Weather services and university networks publish daily max and min temperatures you can paste into the table.

Frequently asked questions

How do you calculate growing degree days?

Average the day’s maximum and minimum temperatures and subtract the base temperature; a negative result counts as zero. For corn, first set any maximum above 86 °F to 86 and any minimum below 50 °F to 50.

What is the difference between GDD and GDU?

None in principle: growing degree units is the term used in corn and seed catalogues for growing degree days computed with the 50/86 °F modified method.

Why is corn GDU capped at 86 °F?

Corn development does not speed up much above about 86 °F (30 °C), so hotter readings are counted as 86 to avoid overstating progress on very hot days.

Can I convert Fahrenheit GDD to Celsius?

Yes: divide by 1.8. A season of 2,700 GDU in °F is 1,500 degree days in °C. Do not subtract 32 — degree days are temperature differences, not temperatures.

What base temperature should I use for wheat?

Most wheat and barley models use 32 °F (0 °C). McMaster and Wilhelm showed that the way cold days are handled — simple versus modified method — changes the totals noticeably for such low bases.

Sources

Last updated:

More Biology calculators

People also use