Insulin resistance means that muscle, liver and fat cells respond less to insulin, so the pancreas has to release more of it to keep blood sugar normal. Measuring it directly requires a hyperinsulinaemic clamp — hours of intravenous infusions in a research unit. In 1985, David Matthews and colleagues in Oxford proposed a shortcut: the homeostasis model assessment (HOMA), which estimates insulin resistance and beta-cell function from a single fasting blood sample containing glucose and insulin.
This calculator gives the classic HOMA1 indices — HOMA-IR (insulin resistance) and HOMA-%B (beta-cell function) — together with QUICKI, an insulin-sensitivity index from the same two values. It accepts glucose in mmol/L, mg/dL or g/L and insulin in µU/mL (the same as mU/L) or pmol/L.
The result is information, not a diagnosis. HOMA-IR was designed for research and population studies; it varies from day to day and between insulin assays, and there is no single "normal" cut-off. Discuss it with your doctor alongside your fasting glucose, HbA1c, weight, waist size and lipids.
How to use this calculator
- Use results from the same fasting sample (usually 8–12 hours without food).
- Choose the glucose unit shown on your report and enter the fasting glucose.
- Choose the insulin unit — µU/mL and mU/L are identical; pmol/L is converted by dividing by 6 — and enter the fasting insulin.
- Read HOMA-IR, the reading against the often-quoted 2.5 cut-off, HOMA-%B and QUICKI. The steps show every conversion and calculation.
The formula
With glucose in mmol/L and insulin in µU/mL (Matthews 1985):
With glucose in mg/dL the constant becomes :
QUICKI (Katz 2000) uses base-10 logarithms, with glucose in mg/dL:
Insulin units: 1 µU/mL = 1 mU/L = 6.00 pmol/L. An older factor of 6.945 still appears on some reports and websites; Knopp and colleagues (2019) showed it rests on an outdated standard and under-estimates insulin by about 15 %.
Worked example
A fasting sample shows glucose 5.0 mmol/L (90 mg/dL) and insulin 12 µU/mL (72 pmol/L).
- HOMA-IR: 2.67 (the same with )
- HOMA-%B: 160.0 %
- QUICKI: 0.330
The glucose is normal, but HOMA-IR is 2.67, above the 2.5 value many studies use, and HOMA-%B of 160.0 % shows the pancreas producing more insulin than the model's young, lean reference (100 %). That pattern — normal sugar maintained by extra insulin — is what HOMA is designed to reveal.
What is a normal HOMA-IR?
The HOMA model was calibrated so that young, normal-weight adults average a HOMA-IR of about 1 and a HOMA-%B of 100 %. Beyond that, there is no universal cut-off. Thresholds published for insulin resistance or metabolic syndrome mostly fall between about 2 and 3, and they differ by country, ethnicity, age, body weight and the insulin assay used. A value of 2.5 is widely quoted — for example in Japanese and Indian studies — so the calculator shows your result against it, but a laboratory or a specialist may use a different threshold.
The authors of the model themselves (Wallace, Levy and Matthews, 2004) recommend HOMA mainly for comparing groups and following trends, not for labelling one person from one test. A single result can also change noticeably from one morning to the next.
HOMA1 vs HOMA2, and when HOMA is not valid
The formulas here are the original HOMA1 equations. The Oxford team later released HOMA2, a computer model that also handles C-peptide and very high glucose; its values are usually lower than HOMA1 values and it cannot be computed by hand. Do not compare a HOMA1 result with a HOMA2 threshold.
HOMA is not meaningful for people injecting insulin (the measured insulin is not the body's own), and it is less reliable with very high fasting glucose. For blood-sugar unit conversions, see the blood sugar converter; for lipids that often travel with insulin resistance, the cholesterol ratio calculator.
Frequently asked questions
What does a high HOMA-IR mean?
It suggests the body needs more insulin than usual to keep fasting glucose normal — a sign of insulin resistance. It is common with excess abdominal weight, inactivity and some conditions such as polycystic ovary syndrome. Only a doctor can interpret it in context.
How do I convert insulin from pmol/L to µU/mL?
Divide by 6: 72 pmol/L = 12 µU/mL. Some sources still divide by 6.945, which gives values about 15 % too low. µU/mL and mU/L are the same unit.
Do I need to be fasting?
Yes. HOMA was built for the fasting steady state. Glucose and insulin rise after a meal, so a non-fasting sample gives a meaningless HOMA-IR.
What is QUICKI and how does it compare?
QUICKI is another fasting index, defined as 1 / (log insulin + log glucose in mg/dL). Lower values mean lower insulin sensitivity. It carries the same information as HOMA-IR on a logarithmic scale.
Can HOMA-IR be improved?
In studies, insulin resistance improves with weight loss when overweight, regular physical activity, better sleep and a diet lower in refined carbohydrates. Any treatment decision belongs to your doctor.
Sources
- Matthews DR et al. Homeostasis model assessment: insulin resistance and β-cell function from fasting plasma glucose and insulin concentrations in man. Diabetologia 1985;28:412–419
- Katz A et al. Quantitative insulin sensitivity check index (QUICKI). J Clin Endocrinol Metab 2000;85:2402–2410
- Wallace TM, Levy JC, Matthews DR. Use and abuse of HOMA modeling. Diabetes Care 2004;27:1487–1495
- Knopp JL et al. Insulin units and conversion factors: a story of truth, boots, and faster half-truths. J Diabetes Sci Technol 2019
- Singh Y et al. A study of insulin resistance by HOMA-IR and its cut-off value to identify metabolic syndrome in urban Indian adolescents. J Clin Res Pediatr Endocrinol 2013
Last updated: