Skip to content

INR Calculator (International Normalized Ratio)

International Normalized Ratio from prothrombin time, mean normal PT and the reagent’s ISI.

Your details

s

Geometric mean PT of at least 20 healthy adults, measured locally with the same reagent and analyser.

s

Printed on the reagent insert; modern reagents are usually between 0.9 and 2.0.

Results update as you type

INR

2.7

PT ratio (PT ÷ mean normal)
2.50
Compared with the range
Within the 2.0–3.0 range

For information and for health professionals. Target ranges are general guidance: the range and any dose change are set by the prescriber.

Step-by-step solution
  1. INR = (30 ÷ 12)^1.1 = 2.5^1.1 = 2.74

This calculator gives estimates for information only and is not medical advice. Talk to a doctor or registered dietitian before making health decisions.

The INR (International Normalized Ratio) is the standard way to report how long blood takes to clot in people taking a vitamin K antagonist such as warfarin, acenocoumarol or fluindione. The raw prothrombin time (PT) in seconds depends heavily on the laboratory reagent: the same blood can clot in 18 seconds with one thromboplastin and 24 with another. The INR removes that difference so that a result of 2.5 means the same thing in Casablanca, Lyon or Boston.

This calculator reproduces the laboratory computation: it divides the patient’s PT by the mean normal PT of the laboratory and raises the ratio to the power of the reagent’s International Sensitivity Index (ISI). It then places the result against a general target range — 2.0–3.0 for most indications, 2.5–3.5 for a mechanical mitral valve — or against the usual values of someone not taking an anticoagulant.

It is meant to help students, laboratory staff and clinicians understand or check a figure. It is for information only and does not replace clinical judgement: the INR target and any change of dose are decided by the prescriber, and point-of-care devices already display a calibrated INR.

How to use this calculator

  1. Enter the patient’s prothrombin time in seconds.
  2. Enter the laboratory’s mean normal PT (the geometric mean of at least 20 healthy adults, measured with the same reagent).
  3. Enter the ISI printed on the thromboplastin insert, ideally the value specific to your analyser.
  4. Choose the target range that applies, or "not on an anticoagulant".
  5. Read the INR, the PT ratio and how the result compares with the range. You can also solve for the PT that corresponds to a chosen INR.

The formula

The WHO calibration model (Kirkwood, 1983) links any thromboplastin to an international reference preparation:

INR=(PTpatientMNPT)ISI\text{INR} = \left(\frac{\text{PT}_{\text{patient}}}{\text{MNPT}}\right)^{\text{ISI}}

where MNPT is the mean normal prothrombin time. The ISI measures how sensitive a reagent is compared with the WHO reference, whose ISI is 1.0. A reagent with ISI 1.0 gives an INR equal to the simple PT ratio; a less sensitive reagent (higher ISI) produces a smaller prolongation in seconds, which the exponent scales back up.

The formula only holds for patients stabilised on a vitamin K antagonist — the population used for calibration. In liver disease or with direct oral anticoagulants the INR is less reliable.

Worked example

A patient’s PT is 30 s, the laboratory’s mean normal PT is 12 s and the reagent ISI is 1.1.

  • PT ratio: 30/12=2.5030 / 12 = 2.50
  • INR: 2.501.1=2.7402.50^{1.1} = 2.740, reported as 2.7 — within the usual 2.0–3.0 range.

The same 30 s measured with a reagent of ISI 1.8 would give 2.501.8=5.2032.50^{1.8} = 5.203, an INR of 5.2: the ISI matters as much as the seconds.

Usual target ranges

Situation General INR target
Not on an anticoagulant about 0.8–1.2
Venous thrombosis, pulmonary embolism, atrial fibrillation, most indications 2.0–3.0 (aim 2.5)
Mechanical mitral valve (ACCP 2012) 2.5–3.5 (aim 3.0)
Mechanical valves in the ESC/EACTS 2021 guideline median 2.5 to 4.0 depending on the valve type and patient risk factors

The 2012 French ANSM guidance on vitamin K antagonists gives the same 2–3 range (target 2.5) for most indications; for mechanical valves the target depends on the prosthesis and on the patient’s risk factors and can reach 4, and a 2.5–4.5 window is used when the target is 3 or more. These figures are general information: each patient’s range is written on their anticoagulant record by the prescriber.

What shifts the INR

  • Diet: large changes in vitamin K intake (green leafy vegetables, some supplements) lower or raise the INR.
  • Medicines: many antibiotics, antifungals, amiodarone and some painkillers increase the effect of vitamin K antagonists; enzyme inducers such as rifampicin reduce it.
  • Illness: fever, diarrhoea, heart failure and liver disease often raise the INR.
  • Alcohol: binge drinking can raise it, chronic heavy use can lower it.

Direct oral anticoagulants (apixaban, rivaroxaban, dabigatran, edoxaban) are not monitored with the INR.

Frequently asked questions

What is a normal INR?

Without an anticoagulant, the INR is usually about 0.8 to 1.2. On a vitamin K antagonist, the usual target is 2.0 to 3.0, and higher for some mechanical heart valves.

Why is the ISI needed to calculate the INR?

Thromboplastin reagents differ in sensitivity. The ISI, determined by calibration against the WHO reference, converts the local PT ratio into the value that would have been obtained with the reference reagent.

What is the difference between INR and prothrombin ratio or "TP %"?

The PT ratio is simply patient PT divided by normal PT. French laboratories also report the prothrombin level as a percentage (taux de prothrombine), used mainly for liver function. Only the INR is standardised across laboratories for monitoring vitamin K antagonists.

Is an INR of 4 dangerous?

It is above the usual 2–3 range and increases bleeding risk. What to do depends on the patient, the indication and any bleeding, so the prescriber or anticoagulation clinic should be contacted rather than adjusting the dose alone.

Does this calculator work for direct oral anticoagulants?

No. Apixaban, rivaroxaban, dabigatran and edoxaban affect the prothrombin time unpredictably, and the INR is not used to monitor them.

Sources

Last updated:

More Health calculators