Skip to content

RAID Calculator: Usable Capacity and Fault Tolerance

Usable capacity, parity overhead, efficiency and fault tolerance of RAID 0, 1, 5, 6, 10, 50, 60 and JBOD.

Your details

Capacity unit

Results update as you type

Usable capacity

12 TB

Usable capacity as shown by most OSes
10.91 TiB
Total raw capacity
16 TB
Parity / mirror overhead
4 TB
Storage efficiency
75%
Drive failures tolerated
1
Read speed (idealized, × one drive)
4 ×
Write speed (idealized, × one drive)
1 ×
Write penalty (I/Os per small write)
4

Speed multiples are idealized random-I/O figures relative to one drive; real arrays depend on the controller, cache, stripe size and workload.

RAID protects against drive failure, not against deletion, ransomware or a fire: keep a separate backup.

Step-by-step solution
  1. RAID 5: 4 × 4 → 3 × 4 = 12 TB
  2. 12 ÷ 16 = 75 %

Before buying disks for a NAS, a home server or a storage array, you want to know two things: how much space you will actually be able to use, and how many drives can die before your data goes with them. This RAID calculator answers both for the common levels: RAID 0, 1, 5, 6, 10, 50, 60 and plain JBOD spanning.

Enter the number of drives and their size, or switch on drives of different sizes to type each capacity. The calculator returns the usable capacity, the space consumed by parity or mirror copies, the storage efficiency in percent, the number of drive failures tolerated, and idealized read and write speed multiples with the write penalty of each level.

The capacity shown is the decimal figure that drive makers print on the box (1 TB = 10^12 bytes). Windows and many NAS dashboards count in binary units (1 TiB = 2^40 bytes), so a second line converts the result to TiB and explains why a "12 TB" array appears as about 10.9 in the operating system.

How to use this calculator

  1. Choose the RAID level. If you are unsure, start with RAID 5 for 3–5 drives or RAID 6 for six drives or more.
  2. Enter the number of drives and the size of each drive, and pick TB or GB.
  3. If your drives are not identical, switch on drives of different sizes and list every capacity, for example 4, 4, 4, 8.
  4. For RAID 50 or RAID 60, set the number of groups: the drives are split evenly into that many RAID 5 or RAID 6 sets.
  5. Read the usable capacity, the overhead, the efficiency and the number of failures the array survives. An error tells you if the level needs more drives or an even count.

The formula

With nn drives, the smallest drive of size ss, and (for RAID 50/60) gg groups, the usable capacity CC is:

Level Usable capacity Failures tolerated Minimum drives
JBOD ∑si\sum s_i 0 1
RAID 0 n⋅sn \cdot s 0 2
RAID 1 ss n−1n-1 2
RAID 5 (n−1) s(n-1)\,s 1 3
RAID 6 (n−2) s(n-2)\,s 2 4
RAID 10 n2 s\frac{n}{2}\,s 1 (up to n/2n/2) 4, even
RAID 50 (n−g) s(n-g)\,s 1 (up to gg) 3g3g
RAID 60 (n−2g) s(n-2g)\,s 2 (up to 2g2g) 4g4g

Efficiency is C/∑siC / \sum s_i. Every level except JBOD reserves the same slice on each member, so extra space on larger drives stays unused. The speed multiples use the classic random-I/O model: reads scale with nn, writes with n/Pn / P, where the write penalty PP is 1 for RAID 0, 2 for RAID 10, 4 for RAID 5/50 (read data, read parity, write data, write parity), 6 for RAID 6/60 and nn for an nn-way mirror. The conversion to binary units is 1 TiB=240 bytes≈1.0995 TB1\ \text{TiB} = 2^{40}\ \text{bytes} \approx 1.0995\ \text{TB}.

Worked example

Four 4 TB drives give very different results depending on the level:

  • RAID 5: (4−1)×4=12(4-1) \times 4 = 12 TB usable, 75 % efficiency, one failure tolerated. The operating system shows about 10.91 TiB. Idealized writes: 4/4=1×4 / 4 = 1\times one drive.
  • RAID 6: (4−2)×4=8(4-2) \times 4 = 8 TB, 50 % efficiency, any two drives can fail.
  • RAID 10: 42×4=8\frac{4}{2} \times 4 = 8 TB, one failure guaranteed and up to two if they hit different mirrors; writes reach 2×2\times.

With mixed sizes 4, 4, 4 and 8 TB in RAID 5, the 8 TB drive only contributes 4 TB: usable capacity is still 12 TB, 4 TB stay unused and efficiency drops to 60 %.

A larger build, twelve 8 TB drives in RAID 60 with two groups of six, keeps (12−2×2)×8=64(12 - 2 \times 2) \times 8 = 64 TB (66.7 %) and survives two failures in each group.

Which RAID level should you choose?

  • RAID 0 is for scratch space and caches where speed matters and the data can be recreated. One dead drive loses everything.
  • RAID 1 is the simplest protection for two drives: a full copy, fast reads, half the capacity.
  • RAID 5 is the classic compromise for 3 to 5 drives. With today's 10 TB+ disks, rebuilding after a failure takes many hours, and a second failure or an unreadable sector during that time can be fatal.
  • RAID 6 tolerates two failures and is the safer default for large drives and arrays of six or more.
  • RAID 10 gives the best random-write performance and fast rebuilds (a mirror copy), at 50 % efficiency. Databases and virtual machines like it.
  • RAID 50 / 60 split very large arrays into groups to shorten rebuilds and raise performance, at the cost of one or two parity drives per group.

Whatever the level, RAID is about availability, not backup: keep at least one copy of important data elsewhere.

Frequently asked questions

Why does my RAID volume look smaller than the calculator says?

Drive makers count 1 TB as 10^12 bytes, while Windows and many tools divide by 2^40 and still print "TB". A 12 TB volume therefore shows as about 10.9. File system metadata and reserved space take a little more.

Can I mix drives of different sizes in a RAID?

Yes, but standard RAID treats every member as if it were the size of the smallest one, so the extra space is wasted until you replace the small drives. Some NAS systems (for example hybrid RAID schemes or ZFS with several vdevs) work around this with their own layouts.

How many drives can fail in RAID 10?

At least one. RAID 10 survives more failures only if each failed drive belongs to a different mirror pair: with 8 drives, up to 4 can fail in the best case, but losing both drives of one pair destroys the array.

Is RAID 5 still safe with large drives?

It works, but the risk window is long: rebuilding a 16 TB drive can take a day or more, during which the array has no redundancy left. For drives above roughly 8 TB, or more than five drives, RAID 6 or RAID 10 is generally recommended.

Are the read and write multiples real speeds?

No, they are idealized ratios against a single drive for small random operations. Controllers, caches, SSD versus HDD, stripe size and sequential workloads change the picture a lot, so use them to compare levels, not to predict benchmarks.

Sources

Last updated:

More Other calculators