Skip to content

Wind Turbine Calculator

Power from rotor size, wind speed and air density (P = ½ρAv³Cp), the Betz limit, and annual energy from a capacity factor.

Your details

Unit system
Calculate

Tip-to-tip diameter (twice the blade length plus the hub). New US onshore turbines averaged about 134 m in 2023.

1.225 kg/m³ is the standard sea-level value at 15 °C. Air is about 10 % thinner at 1,000 m and denser in cold weather.

Share of the wind’s power turned into electricity, all losses included. Large modern turbines reach about 0.45 at best; 0.35–0.40 is a fair average. The Betz limit is 0.593.

Leave blank for the raw formula. If set, the power never exceeds it, as a real turbine pitches its blades above its rated wind speed.

kW

Results update as you type

Turbine power

10.15 kW

Power in the wind
25.37 kW
Betz limit maximum
15.03 kW
Swept area
855.3 sq ft
Power density
319.2 W/m² of wind

Power grows with the cube of wind speed: 10 % more wind gives about 33 % more power. Real turbines start at about 3 m/s, level off at their rated power (often 11–13 m/s) and stop above about 25 m/s.

Power at other wind speeds (same rotor, density and Cp)

How much electricity can a wind turbine make? The answer depends above all on two things: the area swept by the blades and the wind speed, which enters the formula cubed. Double the wind and the power is multiplied by eight; double the rotor diameter and it is multiplied by four. This wind turbine calculator puts those relationships to work in two ways.

Power from wind applies the classic formula P=12ρAv3CpP = \tfrac12\rho A v^3 C_p. Enter the rotor diameter, the wind speed at hub height, the air density and the turbine's power coefficient; you get the electrical power, the total power carried by the wind through the rotor, the theoretical maximum allowed by the Betz limit, the swept area and the power density in W/m². A table and a chart show the power curve from 3 to 25 m/s, and an optional rated power caps the curve the way a real turbine does.

Annual energy answers the question owners and planners actually ask: how many kilowatt-hours per year? Multiply the turbine's rated power by the 8,760 hours of a year and by its capacity factor, the share of that maximum it really delivers. US wind farms averaged about 34 % in 2024 according to the US Energy Information Administration; a small turbine on a sheltered garden site may reach only 10–20 %.

Both modes work for anything from a 1 kW rooftop machine to a 6 MW offshore giant. The formulas are those of standard wind engineering textbooks such as Wind Energy Explained by Manwell, McGowan and Rogers. For the density of air at your site's altitude and temperature, use the air density calculator; to compare with rooftop PV, try the solar panel calculator.

How to use this calculator

  1. Pick Power from wind to size a rotor or check a turbine's output at a given wind, or Annual energy to turn a rated power into kWh per year.
  2. In power mode, enter the rotor diameter, the wind speed at hub height (not ground level, where it is slower) and the air density (1.225 kg/m³ at sea level and 15 °C).
  3. Set the power coefficient Cp: 0.40 is a good default for a modern three-blade turbine; small turbines often reach 0.25–0.35.
  4. Optionally enter the rated power to cap the power curve.
  5. In energy mode, enter the rated power and the expected capacity factor, and read the yearly, monthly and average output.

The formula

The kinetic power of the air crossing the rotor disc is

Pwind=12 ρ A v3,A=πD24P_{\text{wind}} = \tfrac12\,\rho\,A\,v^3, \qquad A = \frac{\pi D^2}{4}

with ρ\rho the air density (kg/m³), AA the swept area (m²), DD the rotor diameter (m) and vv the wind speed (m/s). A turbine converts only a fraction CpC_p of it:

P=12 ρ A v3 Cp,Cp≤1627≈0.593P = \tfrac12\,\rho\,A\,v^3\,C_p, \qquad C_p \le \frac{16}{27} \approx 0.593

The upper bound is the Betz limit (Albert Betz, 1920): to extract energy, the rotor must slow the wind down, and if it stopped the air completely no new air could flow through. The optimum is reached when the wind leaving the rotor has one third of its upstream speed.

Over a year, with rated power PrP_r and capacity factor CFCF:

E=Pr×8760 h×CFE = P_r \times 8760\ \text{h} \times CF

Worked example

A small 10 m rotor in an 8 m/s wind (air at 1.225 kg/m³, Cp = 0.40): the swept area is 78.54 m², the wind carries 24.63 kW through it, the Betz limit would allow at most 14.6 kW, and the turbine delivers 9.85 kW. At 10 m/s the same rotor gives 19.24 kW: 25 % more wind, almost twice the power.

A utility-scale 120 m rotor at 10 m/s sweeps 11,310 m² and would produce about 2,771 kW with Cp = 0.40.

Annual energy: a 2,000 kW turbine with a 35 % capacity factor produces 2,000 × 8,760 × 0.35 = 6,132,000 kWh (6,132 MWh) a year, equivalent to 3,066 hours at full power.

Typical power coefficients and capacity factors

Turbine Cp at best Typical capacity factor
Theoretical (Betz limit) 0.593 —
Modern utility-scale, 3 blades 0.45–0.50 30–45 % onshore, 40–55 % offshore
Small turbine (1–20 kW) 0.25–0.40 10–25 %
Old multi-blade water-pumping windmill 0.15–0.30 —

Cp changes with wind speed: it peaks around 7–10 m/s and falls sharply above rated speed, where the blades are pitched to shed power. That is why the capacity factor, measured over a full year, is the better way to estimate energy. The US wind fleet averaged 34.3 % in 2024 according to the EIA.

Why hub height and site matter so much

Because power follows v3v^3, a site with a 7 m/s average instead of 5 m/s offers about 2.7 times the energy. Wind also strengthens with height above the ground, which is why new US onshore turbines had an average hub height of about 103 m in 2023. Trees, buildings and hills create turbulence that cuts the output of small turbines mounted too low. Measure the wind at the planned height, or use a wind atlas, before trusting any yield estimate.

Frequently asked questions

What is the Betz limit?

The maximum fraction of the wind’s kinetic power that any open rotor can capture: 16/27, or 59.3 %. It follows from conservation of mass and momentum; the best modern turbines achieve 45–50 % after mechanical and electrical losses.

How much electricity does a home wind turbine produce?

A 5 kW turbine with a 15 % capacity factor gives 5 × 8,760 × 0.15 ≈ 6,570 kWh a year. On a poor, turbulent site the capacity factor can drop below 10 %, so measure the wind before buying.

Which wind speed should I enter?

The speed at the height of the hub, not at ground level. For energy, never plug an annual average speed into the cube formula: the mean of v³ is larger than the cube of the mean, so use the capacity-factor mode or a wind speed distribution instead.

How does altitude affect power?

Power is proportional to air density. At 1,500 m density is about 1.06 kg/m³, so the same turbine gives roughly 13 % less power than at sea level. Cold air is denser and adds a few percent in winter.

What is a capacity factor?

The energy actually produced over a year divided by what the turbine would produce running at rated power all 8,760 hours. It accounts for calm periods, winds below rated speed, maintenance and curtailment.

Sources

Last updated:

More Ecology calculators

People also use