How well a layer of insulation slows heat depends on two things only: how thick it is and how conductive the material is. This insulation calculator turns those two numbers into the figures that grant schemes, building codes and product labels use.
In R from thickness mode, enter the thickness and pick a material: you get the thermal resistance R in m²·K/W, the same value as a US R-value (ft²·°F·h/BTU), and the U-value of the element once the standard surface resistances are added. In Thickness for a target R mode, type the R you want — R 7 for an attic, R-38 in US units — and the calculator returns the thickness to install.
Each material comes with a typical declared conductivity λ (lambda). Products vary: two glass-wool rolls on the same shelf can differ by 15 %, so for an exact result choose Other and type the λ printed on the label. Add the floor area and the coverage of one roll or pack to get the quantity to buy.
How to use this calculator
- Choose the mode: R from thickness or Thickness for a target R.
- Pick the material, or choose Other and enter the λ from the product datasheet.
- Enter the thickness (mm, cm or inches), or the target R in SI or US units.
- Choose where it goes (wall, roof, floor) and, if you know it, the R of the other layers, to get a realistic U-value.
- Optionally enter the area and the coverage per roll or pack to get the number of packs, with a waste margin.
The formula
For a homogeneous layer of thickness (m) and declared conductivity (W/(m·K)), ISO 6946 gives:
Resistances of layers in series add up. The U-value of the whole element includes the internal and external surface resistances and :
with and (wall), (roof, heat flowing up) or (floor, heat flowing down). US R-values use imperial units:
Worked example
Attic insulation with 200 mm of glass wool at λ = 0.035:
- m²·K/W, i.e. R-32.4 in US units
- Under a roof: W/(m²·K)
To reach R = 7 with the same wool you need m, about 245 mm; with PIR boards (λ 0.022) only 154 mm. For R-38 with blown cellulose (λ 0.040): R-38 = 6.69 m²·K/W, so 10.5 in after settling.
For 60 m² with 5 % waste you buy 63 m²; with rolls of 4.32 m² that is 15 rolls.
Typical lambda values and thickness for R 7
| Material | Typical declared λ, W/(m·K) | Thickness for R 7 with the default λ (mm) |
|---|---|---|
| Glass wool | 0.032–0.04 | 245 |
| Rock wool | 0.034–0.04 | 252 |
| EPS (white or graphite) | 0.03–0.038 | 224 |
| XPS | 0.029–0.035 | 224 |
| PUR / PIR boards | 0.022–0.028 | 154 |
| Wood fibre | 0.038–0.046 | 280 |
| Cellulose (blown) | 0.039–0.042 | 280 |
Ranges are typical declared values for products on the European and North American markets; the lower the λ, the thinner the layer. Always check the declaration of performance (EU) or the R printed on the bag (US).
Insulation targets: US recommendations and French grant minimums
In the US, the Department of Energy and ENERGY STAR recommend roughly R-30 to R-60 for attics and R-13 to R-21 in wood-framed walls, depending on the climate zone.
In France, the energy-saving certificate scheme (CEE, fiches BAR-EN-101, 102 and 103, versions in force since 1 January 2025, checked October 2026) requires at least R ≥ 7 m²·K/W in lost attics, R ≥ 6 under sloping roofs, R ≥ 3.7 on walls and R ≥ 3 on low floors. MaPrimeRénov’ rules changed in 2026 (single-measure aid for lost attics was withdrawn), so confirm current eligibility on France Rénov’ before signing a quote.
Frequently asked questions
What is the difference between R-value and U-value?
R measures how strongly one layer resists heat flow (higher is better). U is the heat that passes through the whole wall or roof per m² and per degree (lower is better). U is the inverse of the sum of all resistances, including the surface resistances.
How do I convert a US R-value to m²·K/W?
Divide by 5.678. R-38 is about 6.69 m²·K/W and R-13 about 2.29. To go the other way, multiply RSI by 5.678.
What thickness gives R 7?
Multiply 7 by the lambda: about 245 mm of glass wool at 0.035, 280 mm of wood fibre at 0.040 and 154 mm of PIR at 0.022. Loose-fill products need extra thickness to allow for settling.
Does doubling the thickness halve the heat loss?
Doubling the thickness doubles R, but the gain falls off: going from R 2.5 to R 5 saves far more energy than going from R 5 to R 10, because heat loss follows 1/R.
Why is my real wall worse than the calculated R?
Studs, rafters and fixings form thermal bridges, and gaps or compressed insulation lower performance. ISO 6946 adds corrections for these effects; this calculator gives the value for a continuous layer.
Sources
- ISO 6946:2017 — Building components and building elements: thermal resistance and thermal transmittance
- French Ministry of Ecology — CEE standard operation BAR-EN-101 (attic and roof insulation)
- French Ministry of Ecology — CEE standard operation BAR-EN-102 (wall insulation)
- U.S. Department of Energy — Energy Saver: Insulation