Lighting Calculator: Lumens, Bulbs and Running Cost

Lumens and number of bulbs a room needs, LED vs incandescent equivalence and yearly running cost.

Your details

Unit system

Share of the bulbs’ light that reaches the working plane: about 0.6 for open fittings in a light-coloured room, 0.3–0.4 with shades or dark walls.

Allows for dust and the slow loss of output with age; 0.8 is the usual design value.

Printed on the box in lumens: 806 lm replaces a 60 W incandescent bulb, 470 lm a 40 W one.

lm
W
h
$

Results update as you type

Light output needed

6,242 lm

Number of bulbs
8
Target illuminance
150 lx
Target in foot-candles
13.9 fc
Lumens per unit of floor area
29 lm/sq ft
Illuminance with these bulbs
155 lx
Total power
64 W
Incandescent equivalent per bulb
60 W
Energy per year
93.4 kWh
Running cost per year
$18.69
Same light with incandescent bulbs
$140.16
Yearly saving vs incandescent
$121.47

Typical guidance for a living room: 100–300 lx. Add task lighting (desk lamp, under-cabinet strip) where you read, cook or work.

Your bulb gives 101 lm/W. Incandescent bulbs give about 13 lm/W; good LEDs exceed 100 lm/W.

Step-by-step solution
  1. Lumens = E × A ÷ (UF × MF) = 150 lx × 19.97 m² ÷ (0.6 × 0.8) = 6,242 lm
  2. Bulbs = 6,242 ÷ 806 lm = 8 (rounded up)

Is one ceiling light enough for a kitchen, or do you need six spotlights? This lighting calculator answers with the method lighting designers use. Choose the room type — which sets a target brightness in lux — enter the floor area, and it works out the total lumens the room needs and how many bulbs of your chosen output to install.

It then turns the plan into running costs: the total power of the bulbs, the energy used per year at your daily hours of use, the yearly cost at your electricity price and how much you save compared with the same light from old incandescent bulbs, using the official EU equivalence table between lumens and watts.

The target levels are guidance, not regulations: homes are not covered by workplace standards, and taste matters. Use the result as a starting point, then add lamps where you read, cook or work. To price other appliances too, try the electricity cost calculator.

How to use this calculator

  1. Pick the room type. Its usual design illuminance is shown in brackets; choose Custom to type your own value in lux.
  2. Enter the room area in m² or square feet. For an L-shaped room, add the areas of the rectangles (the square footage calculator helps).
  3. Keep the utilization factor at 0.6 for open fittings and light walls, or lower it for shaded lamps and dark décor. Keep the maintenance factor at 0.8 unless you know better.
  4. Enter the light output (lumens) and power (watts) printed on the bulb box.
  5. Enter the hours on per day and your price per kWh to see the yearly energy, cost and saving.

The formula

The lumen method links the light that must reach the working plane to the light the bulbs emit:

Φ=E×AUF×MFN=⌈ΦΦbulb⌉\Phi = \frac{E \times A}{UF \times MF} \qquad N = \left\lceil \frac{\Phi}{\Phi_{\text{bulb}}} \right\rceil

where EE is the target illuminance (lux = lm/m²), AA the area (m²), UFUF the utilization factor (share of emitted light reaching the working plane), MFMF the maintenance factor (allowance for dirt and ageing) and Φbulb\Phi_{\text{bulb}} the output of one bulb. With NN bulbs the average illuminance becomes E′=NΦbulb UF MF/AE' = N \Phi_{\text{bulb}} \, UF \, MF / A.

Energy and cost: kWh/yr=N×P×h×365/1000\text{kWh/yr} = N \times P \times h \times 365 / 1000, cost = kWh × price.

The incandescent equivalent of a bulb comes from the EU equivalence table (806 lm ↔ 60 W, 470 lm ↔ 40 W, 1,521 lm ↔ 100 W…), interpolated linearly between rows and rounded to 1 W, as the regulation prescribes. In foot-candles, 1 fc=1 lm/ft2≈10.76 lx1\ \text{fc} = 1\ \text{lm/ft}^2 \approx 10.76\ \text{lx}.

Worked example

A 20 m² living room, target 150 lx, UF 0.6, MF 0.8, LED bulbs of 806 lm and 8 W, on 4 hours a day at 0.20 per kWh.

  • Lumens needed: 150×20/(0.6×0.8)=6,250150 \times 20 / (0.6 \times 0.8) = 6,250 lm
  • Bulbs: 6,250/806=7.756,250 / 806 = 7.75, rounded up to 8 bulbs, giving about 155 lx
  • Power: 8 × 8 W = 64 W, so 93.4 kWh and 18.69 a year
  • Each 806 lm bulb replaces a 60 W incandescent bulb: 480 W in total, 700.8 kWh and 140.16 a year — a saving of 121.47 a year.

Recommended light levels by room

Room Guidance range Value used
Hallway, stairs 50–150 lx 100 lx
Bedroom 50–150 lx 100 lx
Living room 100–300 lx 150 lx
Dining room 150–300 lx 200 lx
Bathroom 150–300 lx 200 lx
Kitchen 300–500 lx (worktops at the top of the range) 300 lx
Garage, workshop 200–500 lx 300 lx
Home office, study 300–500 lx 500 lx

For workplaces the European standard EN 12464-1 sets maintained values such as 500 lx for writing, typing and reading and 100 lx for corridors; the home values above are commonly quoted guidance and leave room for personal taste. Older eyes need more light: someone aged 60 typically needs far more light on a page than a 20-year-old.

LED vs incandescent: lumens, watts and efficacy

Light output Incandescent (EU table) Typical LED
136 lm 15 W 1.5–2 W
249 lm 25 W 2.5–3 W
470 lm 40 W 4–5 W
806 lm 60 W 7–9 W
1,055 lm 75 W 9–11 W
1,521 lm 100 W 13–16 W

Incandescent bulbs give about 13 lm/W and current LEDs typically 90–150 lm/W. The US Lighting Facts label rounds the same equivalences (about 450 lm for 40 W, 800 lm for 60 W, 1,600 lm for 100 W). Between table rows, the calculator interpolates: 638 lm counts as 50 W.

Frequently asked questions

How many lumens do I need for a room?

Multiply the target lux by the floor area in m², then divide by the utilization and maintenance factors (0.6 × 0.8 = 0.48 by default). A 20 m² living room at 150 lx needs about 6,250 lm from the bulbs.

What is the difference between lumens and lux?

Lumens measure the total light a bulb emits; lux measures how much of it lands on each square metre. One lux is one lumen per m², and one foot-candle is one lumen per square foot, about 10.76 lx.

What LED replaces a 60 W bulb?

Look for about 806 lm (the EU equivalence) or 800 lm (the US label). Most such LEDs draw 7 to 9 W, roughly an eighth of the power.

Why is the utilization factor so important?

Not all emitted light reaches the table or floor: shades, fittings and dark walls absorb part of it. With a factor of 0.4 instead of 0.6 you need 50% more lumens for the same result.

Are these light levels mandatory?

No. Homes are not covered by workplace lighting standards; the values are guidance. Workplaces in Europe follow EN 12464-1 and national labour rules.