Almost every chemical reaction speeds up when it gets warmer, and the Arrhenius equation says by how much. It links the rate constant to the absolute temperature through two parameters of the reaction: the activation energy , the energy barrier molecules must cross to react, and the pre-exponential factor , which reflects how often molecules collide in a suitable orientation.
The calculator has three modes:
- Rate constant k: enter A, Ea and T to get k, the Boltzmann factor and the Q₁₀ factor (how many times faster the reaction goes 10 °C higher).
- Activation energy: enter two rate constants measured at two temperatures. The calculator applies the two-point Arrhenius equation and returns Ea in kJ/mol, kcal/mol and eV per molecule, plus the pre-exponential factor A.
- k at new T: enter one rate constant, its temperature and Ea to predict the rate constant at another temperature, for example to estimate shelf life at room temperature from an accelerated test.
Temperatures can be typed in kelvins, degrees Celsius or Fahrenheit; they are always converted to kelvins, which the equation requires. Rate constants may be in any unit, as long as both points use the same one. For the time a first-order reaction takes to consume half its reactant, see the half-life calculator.
How to use this calculator
- Choose what to calculate: Rate constant k, Activation energy or k at new T.
- Enter the known values. Large or tiny numbers can be typed in scientific notation (1e10, 3.52e-7).
- Pick the temperature unit next to each temperature and the energy unit for Ea.
- Read the result and the working, which shows each term of the equation with the temperatures in kelvins.
The formula
The Arrhenius equation and its logarithmic form:
Writing it at two temperatures and subtracting eliminates (two-point form):
= 8.314462618 J·mol⁻¹·K⁻¹ (exact in the 2019 SI), in kelvins. Unit conversions used: 1 kcal/mol = 4.184 kJ/mol and 1 eV per molecule = 96.485 kJ/mol. The temperature coefficient is .
Worked example
Rate constant. A first-order reaction with s⁻¹ and = 75 kJ/mol at 25 °C (298.15 K) has
and its rate is multiplied by 2.67 if the temperature rises to 35 °C.
Activation energy from two points. The decomposition of N₂O₅ has = 1.66 L·mol⁻¹·s⁻¹ at 650 K and = 7.39 L·mol⁻¹·s⁻¹ at 700 K (OpenStax Chemistry 2e). The two-point equation gives Ea = 112.99 kJ/mol (27 kcal/mol), i.e. about 1.1 × 10⁵ J/mol, and ≈ 1.994 × 10⁹ L·mol⁻¹·s⁻¹.
Rate at a new temperature. With Ea = 113 kJ/mol, the same reaction at 750 K has ≈ 26.97 L·mol⁻¹·s⁻¹, about 16 times faster than at 650 K.
Activation energy calculator: getting Ea from experiments
To find an activation energy, measure the rate constant (or any quantity proportional to it, such as an initial rate or the inverse of a reaction time) at two or more temperatures. With two points, the Activation energy mode solves the two-point equation directly. With more points, plot against : the data should fall on a straight line (an Arrhenius plot) whose slope is and whose intercept is . A straight line also confirms that the Arrhenius model fits; curvature suggests a change of mechanism.
Some practical advice: use temperatures at least 10–20 K apart, because the result depends on the small difference and measurement errors are amplified when the temperatures are close. Always convert to kelvins; using °C in the formula gives wrong answers. Typical values:
| Process | Typical Ea |
|---|---|
| Diffusion-controlled reactions in water | 10–20 kJ/mol |
| Enzyme-catalysed reactions | 25–60 kJ/mol |
| Many organic reactions near room temperature | 50–100 kJ/mol |
| Thermal decomposition of stable molecules | 150–400 kJ/mol |
The "rate doubles every 10 °C" rule
A popular rule of thumb says reaction rates double for every 10 °C rise. The Arrhenius equation shows when that is true: near room temperature, a reaction with Ea ≈ 50 kJ/mol has ≈ 1.92, while one with 75 kJ/mol speeds up 2.67 times. The higher the barrier, the more sensitive the reaction is to temperature, which is why refrigeration slows food spoilage so effectively and why accelerated ageing tests at 40–60 °C can predict shelf life only if Ea is known.
Frequently asked questions
How do I calculate activation energy from two rate constants?
Use Ea = R × ln(k₂/k₁) / (1/T₁ − 1/T₂) with temperatures in kelvins and R = 8.314 J/(mol·K). The result is in J/mol; divide by 1000 for kJ/mol. The “Activation energy” mode does this and also returns A.
What is the pre-exponential factor A?
A is the rate constant the reaction would have if every collision had enough energy, i.e. at infinite temperature. It has the same unit as k and reflects collision frequency and orientation. For first-order reactions it is often 10¹⁰ to 10¹⁴ s⁻¹.
Why must the temperature be in kelvins?
The equation contains 1/T and comes from the Boltzmann distribution, which uses absolute temperature. Using °C would give a different and meaningless result, and 0 °C would cause a division by zero.
Can activation energy be negative?
For an elementary reaction, no. An apparent negative value means the measured rate falls as temperature rises, which happens for some multi-step reactions where a pre-equilibrium shifts backwards. The calculator reports it with a note.
How do I convert activation energy between kJ/mol, kcal/mol and eV?
1 kcal/mol = 4.184 kJ/mol, and 1 eV per molecule = 96.485 kJ/mol. So 100 kJ/mol ≈ 23.9 kcal/mol ≈ 1.04 eV. Choose the unit with the buttons next to Ea.
Sources
- IUPAC Gold Book — Arrhenius equation
- IUPAC Gold Book — activation energy (Arrhenius activation energy)
- OpenStax Chemistry 2e — 12.5 Collision Theory
- BIPM SI Brochure (9th ed.) — exact R = N_A·k and elementary charge