In a closed space above water, molecules keep leaving the liquid until the vapour above it reaches a balance: the saturation vapor pressure. It depends only on temperature, and it rises steeply — about 0.6 kPa at 0 °C, 3.2 kPa at 25 °C, 12.3 kPa at 50 °C and one full atmosphere at 100 °C, which is exactly why water boils there. It is the key quantity behind relative humidity, the dew point, evaporation, cloud formation, drying and distillation.
This calculator gives the saturation vapor pressure of liquid water or of ice at the temperature you enter, using the international reference equations of the IAPWS, and compares them with the four empirical formulas you are most likely to meet in textbooks and software:
- Buck (1996) — the meteorologist's high-accuracy fit;
- Magnus with the Alduchov–Eskridge coefficients — the form used in most dew-point formulas;
- Tetens — the classic agronomy form (FAO-56);
- Antoine — the chemistry-textbook equation, here with the well-known set for 1–100 °C.
In boiling point mode the calculation runs backwards: enter a pressure — at altitude, in a pressure cooker or under vacuum — and get the temperature at which water boils. Results can be shown in Pa, hPa, kPa, mbar, bar, atm, mmHg, torr, psi or inHg.
How to use this calculator
- Choose Vapor pressure or Boiling point.
- For vapor pressure, choose liquid water or ice and enter the temperature in °C, °F or K. Below 0 °C, "liquid water" means supercooled water, as in clouds.
- For the boiling point, enter the ambient pressure in any unit. The help text lists standard-atmosphere pressures at a few altitudes.
- Read the reference value, the comparison formulas and the saturation vapor density (grams of water vapor per cubic metre). Switch the pressure unit on any result.
The formula
Reference (IAPWS-IF97, liquid water, 0–373.946 °C). With in kelvin, , , , :
The same quadratic solved for gives the boiling point at pressure . Over ice, IAPWS (2011) gives with K and Pa.
Empirical formulas ( in °C):
Over ice, Buck uses hPa, Magnus hPa and Tetens kPa.
Worked example
At 25 °C the IAPWS-IF97 value is 3.170 kPa (23.8 mmHg). Buck gives 3.169 kPa, Tetens 3.168 kPa and Antoine 3.158 kPa — all within half a percent. Air saturated at 25 °C holds about 23.0 g of water vapor per m³.
At 100 °C IF97 gives 101.42 kPa and Buck 101.31 kPa, essentially one standard atmosphere (101.325 kPa). On the modern temperature scale, water boils at 99.97 °C at exactly 101.325 kPa.
Ice versus supercooled water at −10 °C: 259.9 Pa over ice but 286.6 Pa over supercooled droplets. That gap is why ice crystals grow at the expense of droplets in mixed clouds.
Boiling at altitude: at 2,000 m the standard pressure is about 79.5 kPa, and water boils at 93.3 °C — which is why pasta and eggs take longer to cook in the mountains.
How the formulas compare (kPa, over liquid water)
| T (°C) | IAPWS-IF97 | Buck | Magnus | Tetens | Antoine |
|---|---|---|---|---|---|
| 0 | 0.6112 | 0.6112 | 0.6109 | 0.6108 | — |
| 10 | 1.2282 | 1.2279 | 1.2260 | 1.2280 | 1.2211 |
| 20 | 2.3392 | 2.3383 | 2.3334 | 2.3383 | 2.3296 |
| 30 | 4.2467 | 4.2451 | 4.2367 | 4.2431 | 4.2317 |
| 40 | 7.3844 | 7.3824 | 7.3747 | 7.3756 | 7.3584 |
| 50 | 12.3513 | 12.3494 | 12.3606 | 12.3368 | 12.3056 |
| 60 | 19.9458 | 19.9451 | 20.0230 | 19.9331 | 19.8702 |
| 80 | 47.4147 | 47.4103 | 48.0397 | 47.5249 | 47.2671 |
| 100 | 101.4180 | 101.3078 | 104.0767 | 102.2157 | 101.3365 |
Between 0 and 50 °C, Buck stays within about 0.05 % of the reference, Magnus and Tetens within about 0.25 % and Antoine within about 0.6 % — all better than typical humidity sensors. Above 50 °C, Magnus and Tetens drift upwards (about +2.6 % and +0.8 % at 100 °C) because they were fitted for atmospheric conditions; use IAPWS-IF97 for laboratory and engineering work. Antoine is not defined below 1 °C with this coefficient set.
Vapor pressure, humidity and boiling
Relative humidity is the ratio of the actual partial pressure of water vapor to the saturation vapor pressure at the air temperature. When warm air cools, its saturation pressure drops until it equals the actual vapor pressure: that temperature is the dew point. A wet-bulb thermometer uses the same idea, cooling by evaporation until it balances the dryness of the air.
A liquid boils when its vapor pressure equals the pressure above it. Lower the pressure (mountains, vacuum distillation, freeze-drying) and water boils colder; raise it (pressure cooker at about 200 kPa absolute, steam boilers) and it boils hotter, up to the critical point at 373.946 °C and 22.064 MPa where liquid and vapor become indistinguishable.
Frequently asked questions
What is the vapor pressure of water at 25 °C?
About 3.170 kPa, i.e. 23.8 mmHg or 31.7 hPa, according to the IAPWS-IF97 standard. Common textbook tables round it to 3.17 kPa or 23.8 mmHg.
What is the boiling point of water at a given pressure?
It is the temperature at which the saturation vapor pressure equals that pressure. Choose Boiling point mode and enter the pressure: 101.325 kPa gives 99.97 °C, 79.5 kPa (about 2,000 m altitude) gives about 93.3 °C, 200 kPa gives about 120 °C.
Which formula is the most accurate?
The IAPWS formulations are the international reference: IF97 for liquid water from 0 °C to the critical point and the 2011 sublimation equation for ice. Buck (1996) is the best of the simple formulas for atmospheric temperatures; Magnus and Tetens are convenient approximations.
Why is the vapor pressure lower over ice than over water?
Molecules are held more tightly in the ice lattice, so fewer escape at the same temperature. Below 0 °C, air that is just saturated with respect to supercooled water is supersaturated with respect to ice, which drives frost formation and snowflake growth.
Does dissolved salt change the vapor pressure?
Yes. By Raoult’s law, the vapor pressure of the solvent is roughly its mole fraction times the pure-water value, so seawater (about 3.5 % salt) has a vapor pressure about 2 % lower than fresh water. This calculator gives the values for pure water.
Sources
- IAPWS R7-97(2012), Revised Release on the IAPWS Industrial Formulation 1997 (IAPWS-IF97), §8 Region 4
- IAPWS R14-08(2011), Revised Release on the Pressure along the Melting and Sublimation Curves of Ordinary Water Substance
- Buck A. L. (1981), New equations for computing vapor pressure and enhancement factor, J. Appl. Meteor. 20:1527–1532
- Alduchov O. A. & Eskridge R. E. (1996), Improved Magnus form approximation of saturation vapor pressure, J. Appl. Meteor. 35:601–609
- FAO Irrigation and Drainage Paper 56, chapter 3, Eq. 11 (Tetens form)
- Vömel H., Saturation vapor pressure formulations (CIRES, University of Colorado)