Skip to content

Flow Rate Calculator: Litres per Minute, m³/h and gpm

Flow rate from a bucket test or from pipe diameter and velocity, water speed in a pipe, and L/min ↔ m³/h ↔ gpm conversion.

Your details

Unit system
Calculate

For a bucket test, use a container whose volume you know and fill it from the tap or hose.

Results update as you type

Litres per minute

47.3176 L/min

Litres per second
0.788627 L/s
Cubic metres per hour
2.83906 m³/h
US gallons per minute
12.5 US gpm
UK gallons per minute
10.4084 UK gpm
Cubic feet per second
0.02785 ft³/s
Cubic feet per minute
1.67101 ft³/min (CFM)

Step-by-step solution
  1. Q = V ÷ t = 18.9271 L ÷ 24 s = 0.788627 L/s
  2. 0.000789 m³/s × 60,000 = 47.3176 L/min

Flow rate is the volume of fluid that passes a point per unit of time. It tells you whether a shower head meets its rating, whether a well pump keeps up with the irrigation, how big a pipe must be or how long a pool will take to fill. This flow rate calculator covers the four questions people actually ask:

  • Volume ÷ time — the bucket test: fill a known container and time it.
  • Pipe flow — the flow carried by a round pipe from its inner diameter and the mean velocity of the fluid.
  • Pipe velocity — the reverse: how fast the water moves for a given flow and diameter.
  • Convert — between litres per second, litres per minute, litres per hour, m³/h, m³/s, US and UK gallons per minute, ft³/s and CFM.

Every result is shown in L/min, L/s, m³/h, US gpm, UK gpm, ft³/s and ft³/min at once, so you can compare a European pump curve with an American fixture rating without a second tool. You can also solve backwards: pick a target flow and let the calculator find the filling time, the pipe diameter or the velocity.

How to use this calculator

  1. Choose what to calculate.
  2. Volume ÷ time: enter the volume collected (for example a 10 L bucket) and the seconds it took to fill.
  3. Pipe flow: enter the inner diameter of the pipe and the mean flow velocity.
  4. Pipe velocity: enter the flow rate with its unit and the inner diameter.
  5. Convert: enter a flow rate and its unit to see it in every other unit.
  6. Read the results; the steps show the arithmetic and the cross-sectional area used.

The formula

Volumetric flow rate QQ is a volume divided by a time, or a cross-sectional area multiplied by the mean velocity:

Q=VtQ=A vˉA=πd24Q = \frac{V}{t} \qquad Q = A\,\bar v \qquad A = \frac{\pi d^2}{4}

so the mean velocity in a round pipe of inner diameter dd is

vˉ=4Qπd2\bar v = \frac{4Q}{\pi d^2}

Because the area grows with the square of the diameter, doubling the diameter divides the velocity by four for the same flow. Unit factors used (exact):

Unit In L/min In m³/h
1 L/s 60 3.6
1 L/h 0.016667 0.001
1 m³/h 16.6667 1
1 US gpm 3.78541 0.227125
1 US gph 0.06309 0.003785
1 UK gpm 4.54609 0.272765
1 ft³/s 1,699.01 101.941
1 ft³/min (CFM) 28.3168 1.69901

Worked example

Bucket test: a 10 L bucket fills in 24 s. Q=10/24=0.4167Q = 10 / 24 = 0.4167 L/s, i.e. 25 L/min, 1.5 m³/h or 6.6043 US gpm.

Pipe flow: water moves at 2 m/s in a pipe with a 25 mm bore. A=π×0.0252/4=4.9087A = \pi \times 0.025^2 / 4 = 4.9087 cm², so Q=A×vQ = A \times v = 58.905 L/min (3.5343 m³/h).

Pipe velocity: a pump delivers 100 L/min through a 50 mm pipe (A=19.635A = 19.635 cm²). The mean speed is 0.849 m/s. Through a 32 mm pipe it would rise to 2.07 m/s.

Conversion: a 10 US gpm well pump delivers 37.854 L/min.

Flow rate (débit) in everyday terms

Flow rate is called débit in French and is the same quantity everywhere: volume per time. A kitchen tap typically gives a few litres per minute, a garden hose somewhat more, a fire hose hundreds. Water bills count volume, pumps are rated in flow at a given head, and fixtures are labelled in L/min or gpm — all of these are flow rates expressed in different units.

Pipe flow and pipe sizing

For a given flow, a smaller pipe means a higher velocity, more friction loss and more noise. A widely used rule of thumb for water in pressure pipes is to stay roughly between 0.5 and 3 m/s; the calculator warns above 3 m/s. Use Pipe flow and solve for the diameter to find the bore that carries your flow at a chosen speed, then pick the next standard size up. Exact sizing also depends on pressure loss, length and fittings, which this tool does not model.

Litres per minute: the bucket test

To measure litres per minute at a tap, shower or hose: open it fully, hold a container of known volume under it and time the fill with a stopwatch. Divide the litres by the seconds and multiply by 60. Repeat two or three times and average; with a 10 L bucket, one second of timing error changes the result by about 4%, so a larger container gives a better estimate.

Frequently asked questions

How do I convert m³/h to litres per minute?

Multiply by 1,000 to get litres per hour, then divide by 60: 1 m³/h = 16.667 L/min. The other way, 1 L/min = 0.06 m³/h.

How many litres per minute is 1 gpm?

One US gallon per minute is 3.785 L/min; one UK (imperial) gallon per minute is 4.546 L/min. Check which gallon your datasheet uses.

Should I use the inner or outer pipe diameter?

The inner (bore) diameter, because only the open area carries fluid. Nominal sizes and outside diameters overestimate the area, especially for thick-walled plastic pipe.

Does the formula work for air and other gases?

Yes for volumetric flow at the conditions in the pipe. Gas volume changes with pressure and temperature, so compare flows at the same conditions or convert with the ideal gas law.

Why is the velocity called the mean velocity?

Fluid moves fastest in the centre of a pipe and slowest at the wall. Q = A·v uses the average over the cross-section, which is what the flow rate defines.

Sources

Last updated:

More Physics calculators

People also use