Results update as you type

Carnot efficiency

54.97%

Hot reservoir
673.15 K
Cold reservoir
303.15 K

The Carnot value is an upper bound for any engine, refrigerator or heat pump between these two temperatures; real machines reach well below it.

Step-by-step solution
  1. Th = 673.15 K, Tc = 303.15 K
  2. η = 1 − Tc ÷ Th = 1 − 303.15 ÷ 673.15 = 0.549655

No heat engine can turn all the heat it receives into work. In 1824 Sadi Carnot showed that the best any engine can do depends only on the temperatures of the hot source and the cold sink it works between — not on the fuel, the working fluid or the cleverness of the design. That upper bound is the Carnot efficiency, and the same reasoning sets the maximum coefficient of performance (COP) of refrigerators, air conditioners and heat pumps.

This Carnot efficiency calculator converts your temperatures from °C, °F or K to kelvin and gives:

  • for a heat engine: the maximum efficiency 1−Tc/Th1 - T_c/T_h and, if you enter the heat supplied, the most work you could ever extract and the least heat that must be thrown away;
  • for a refrigerator or air conditioner: the Carnot COP Tc/(Th−Tc)T_c/(T_h - T_c) and the minimum work needed to remove a given amount of heat;
  • for a heat pump: the Carnot COP Th/(Th−Tc)T_h/(T_h - T_c) and the minimum electricity needed to deliver a given amount of heat;
  • the second-law efficiency of a real machine when you enter its actual efficiency or COP — the fraction of the ideal performance it actually achieves.

The calculator refuses temperatures at or below absolute zero, a cold side hotter than the hot side, and real performance figures that beat the Carnot limit, since those would violate the second law.

How to use this calculator

  1. Choose the machine: heat engine, refrigerator or heat pump.
  2. Enter the hot and cold reservoir temperatures in °C, °F or K. The calculator converts them to kelvin; never use Celsius directly in the formula.
  3. Optionally enter the machine's actual efficiency (engine) or actual COP (refrigerator, heat pump) to get its second-law efficiency.
  4. Optionally enter a quantity of heat to see the maximum work output, or the minimum work input, and the heat exchanged on the other side.
  5. Read the result with the step-by-step working.

The formula

All temperatures are absolute (kelvin): T=θ°C+273.15T = \theta_{°C} + 273.15. For a reversible engine operating between a hot reservoir ThT_h and a cold reservoir TcT_c:

ηC=WQh=1−TcTh\eta_C = \frac{W}{Q_h} = 1 - \frac{T_c}{T_h}

Running the same cycle backwards, the coefficients of performance are

KR=QcW=TcTh−TcKP=QhW=ThTh−Tc=KR+1K_R = \frac{Q_c}{W} = \frac{T_c}{T_h - T_c} \qquad K_P = \frac{Q_h}{W} = \frac{T_h}{T_h - T_c} = K_R + 1

Energy conservation links the heats and the work: Qh=Qc+WQ_h = Q_c + W. The second-law efficiency compares a real machine with the reversible one:

ηII=ηactualηCorηII=COPactualCOPCarnot\eta_{II} = \frac{\eta_{actual}}{\eta_C} \quad\text{or}\quad \eta_{II} = \frac{COP_{actual}}{COP_{Carnot}}

Worked example

Steam engine between 400 °C and 30 °C. In kelvin, ThT_h = 673.15 K and TcT_c = 303.15 K, so ηC=1−303.15/673.15\eta_C = 1 - 303.15/673.15 = 54.97%. With 100 kJ of heat from the boiler, at most 55 kJ can become work. If the real engine reaches 35 %, its second-law efficiency is 63.7%.

Heat pump between 0 °C outside and 20 °C inside (the case worked in OpenStax). KP=293.15/20K_P = 293.15/20 = 14.66: delivering 30 kJ of heat indoors needs at least 2.05 kJ of work, while 27.95 kJ is drawn from the cold outdoor air.

Freezer at −18 °C in a 25 °C kitchen. KR=255.15/43K_R = 255.15/43 = 5.93. A real freezer with a COP of 2 therefore works at about 33.7% of the Carnot limit.

Why real engines fall short of Carnot

The Carnot cycle is made of two isothermal and two adiabatic steps, all perfectly reversible: heat flows across vanishingly small temperature differences and nothing rubs. Real machines need finite temperature differences to move heat at a useful rate, and they lose energy to friction, turbulence and leaks. A modern steam power plant with steam at about 565 °C and a condenser near 30 °C has a Carnot limit of about 63.8%, yet delivers 35–45 %. Car petrol engines reach 25–35 %. That is why the second-law efficiency is a fairer score than the raw efficiency: it tells you how much of the theoretically available work a machine actually captures.

The formula also explains two engineering habits: raise the hot temperature (gas turbines, supercritical boilers) and lower the cold one (cooling towers, cold sea water) to widen the gap.

Heat pump and refrigerator COP

A COP above 1 is not a violation of energy conservation: a heat pump moves heat rather than creating it, so 1 kWh of electricity can deliver 3 or 4 kWh of heat. The Carnot COP shows why heat pumps work best with a small temperature lift: underfloor heating at 35 °C fed from ground at 10 °C has a far higher ceiling than radiators at 55 °C fed from air at −10 °C. For the energy needed to heat water or a material, see the specific heat calculator; for the gas relations behind the cycle, the ideal gas law calculator.

Frequently asked questions

What is the Carnot efficiency formula?

η = 1 − Tc/Th, where Th and Tc are the absolute temperatures (in kelvin) of the hot and cold reservoirs. Multiply by 100 for a percentage.

Why must temperatures be in kelvin?

Because the formula uses ratios of temperatures, which only make sense on an absolute scale that starts at zero energy. Using Celsius gives nonsense: 1 − 30/400 would suggest 92.5 % instead of the correct 54.97 % for 400 °C and 30 °C.

Can any engine be more efficient than a Carnot engine?

No. Carnot’s theorem, a consequence of the second law of thermodynamics, states that no engine working between the same two temperatures can beat a reversible engine. All reversible engines between those temperatures share the same efficiency.

What is the maximum COP of a heat pump?

Th/(Th − Tc) with absolute temperatures. Between 0 °C and 20 °C it is 14.66. Real air-source heat pumps achieve roughly 3 to 4 under such conditions, a second-law efficiency of about 20–30 %.

What is second-law efficiency?

The ratio of a machine’s actual performance to the best performance allowed by thermodynamics under the same conditions. An engine at 35 % efficiency where Carnot allows 55 % has a second-law efficiency of about 64 %.