Bernoulli Equation Calculator

Solve Bernoulli’s equation for pressure, velocity or height, with pipe continuity and a Venturi meter mode.

Your details

Unit system
Calculation

A₁v₁ = A₂v₂: the velocity at point 2 follows from v₁ and the two inside diameters.

Results update as you type

Pressure P₂

25.0702 psi

Velocity v₂ (continuity)
24 ft/s
Flow rate Q
3.7067 L/s
Flow rate Q (m³/h)
13.344 m³/h
Flow rate Q (US gpm)
58.752 gal/min
Mass flow rate
3.7 kg/s
Dynamic pressure ½ρv₁²
0.2421 psi
Dynamic pressure ½ρv₂²
3.8737 psi
Total pressure P + ½ρv² + ρgh
30.2421 psi

Ideal flow: steady, incompressible, frictionless, along one streamline, no pump or turbine in between. For gases, valid below about Mach 0.3.

Step-by-step solution
  1. P₁ + ½ρv₁² + ρgh₁ = P₂ + ½ρv₂² + ρgh₂ = 30.2421 psi
  2. v₂ = v₁·(d₁ ÷ d₂)² = 24 ft/s
  3. P₂ = 25.0702 psi

Bernoulli's equation is the energy balance of a moving fluid. Along a streamline of steady, frictionless, incompressible flow, the sum of the static pressure PP, the dynamic pressure 12ρv2\tfrac{1}{2}\rho v^2 and the hydrostatic term ρgh\rho g h stays the same. Speed the fluid up and its pressure drops; lift it and its pressure drops too. That single idea explains why a garden-hose nozzle sprays far, how an aircraft wing generates part of its lift, and how a carburettor or a perfume atomiser draws liquid into a fast air stream.

This Bernoulli equation calculator compares two points of a flow. Pick the unknown (pressure, velocity or height at point 1 or point 2), enter the other five values and choose the fluid. Turn on continuity and the calculator works out the velocity at point 2 from the two pipe diameters, because the same volume per second must pass through every section: A1v1=A2v2A_1 v_1 = A_2 v_2. You then also get the flow rate in L/s, m³/h and US gallons per minute.

The Venturi meter mode applies the same physics to the classic flow meter: a pipe narrows to a throat, the pressure falls there, and the measured pressure difference gives the flow. Enter the inlet and throat diameters and the pressure difference; add a discharge coefficient to account for real-world losses.

Pressures can be absolute or gauge, as long as you use the same kind at both points. Results include each step and the total pressure that stays constant along the streamline.

How to use this calculator

  1. Choose Bernoulli equation or Venturi meter.
  2. Choose the fluid (water, seawater, air, gasoline) or enter your own density.
  3. In Bernoulli mode, pick the unknown and fill in the five other values: pressure, velocity and height at points 1 and 2. Heights are measured from any common reference level.
  4. Leave continuity on to derive v2v_2 from the inside diameters d1d_1 and d2d_2; switch it off to type v2v_2 yourself.
  5. In Venturi mode, enter d1d_1, the throat diameter d2d_2, the measured pressure difference P1−P2P_1 - P_2 and, optionally, the discharge coefficient.
  6. Read the result, the flow rate and the steps.

The formula

Between two points 1 and 2 on the same streamline:

P1+12ρv12+ρgh1=P2+12ρv22+ρgh2P_1 + \tfrac{1}{2}\rho v_1^2 + \rho g h_1 = P_2 + \tfrac{1}{2}\rho v_2^2 + \rho g h_2

with ρ\rho the density, g=9.80665g = 9.80665 m/s² and hh the height above a reference level. For a pipe of circular cross-section, conservation of mass (continuity) gives

A1v1=A2v2⇒v2=v1(d1d2)2A_1 v_1 = A_2 v_2 \quad\Rightarrow\quad v_2 = v_1 \left(\frac{d_1}{d_2}\right)^2

For a horizontal Venturi meter, combining both with β=d2/d1\beta = d_2/d_1:

v2=2 (P1−P2)ρ (1−β4)Q=C A2 v2v_2 = \sqrt{\frac{2\,(P_1 - P_2)}{\rho\,(1 - \beta^4)}} \qquad Q = C\,A_2\,v_2

where CC is the discharge coefficient (1 for the ideal device).

Worked example

Water rising through a narrowing pipe (calculator defaults): P1=200P_1 = 200 kPa, v1=2v_1 = 2 m/s at h1=0h_1 = 0; the pipe narrows from 50 mm to 25 mm, so v2=2×(50/25)2=8v_2 = 2 \times (50/25)^2 = 8 m/s at h2=1h_2 = 1 m. With ρ=998.2\rho = 998.2 kg/m³, the dynamic pressure rises from 1.9964 kPa to 31.9424 kPa and lifting the water by 1 m costs 9.789 kPa, so P2P_2 = 160.265 kPa. The flow rate is 3.927 L/s.

Garden hose (OpenStax example 14.6): water at 1.96 m/s in the hose leaves a level nozzle at 25.5 m/s into air at 1.01×1051.01 \times 10^5 Pa. With ρ=1000\rho = 1000 kg/m³, the pressure in the hose is P1P_1 ≈ 424.2 kPa absolute.

Venturi meter: water, d1=100d_1 = 100 mm, d2=50d_2 = 50 mm, P1−P2=15P_1 - P_2 = 15 kPa. Then β=0.5\beta = 0.5, the throat velocity is 5.662 m/s and the ideal flow is 11.12 L/s; with C=0.984C = 0.984 it is about 10.94 L/s.

The Bernoulli principle and the Venturi effect

The Venturi effect is the pressure drop in a constriction. Because A1v1=A2v2A_1 v_1 = A_2 v_2, the fluid must speed up where the pipe narrows, and since the total P+12ρv2P + \tfrac{1}{2}\rho v^2 is constant on level ground, the static pressure must fall. A Venturi meter measures that fall with two pressure taps or a U-tube manometer and converts it into a flow rate; its smooth converging and diverging cones recover most of the pressure afterwards, which is why it wastes less energy than an orifice plate. For the flow itself and pipe sizing, see the flow rate calculator.

When Bernoulli’s equation does not apply

Real pipes have friction, bends and valves, and they lose pressure even at constant speed and height. Bernoulli's equation leaves those losses out; for long pipes, add a head-loss term with the pressure drop calculator. The equation also fails across pumps, fans or turbines (they add or remove energy), in strongly unsteady flow, and for gases moving faster than about 30 % of the speed of sound, where compressibility matters. Check the flow regime with the Reynolds number calculator.

Frequently asked questions

What does Bernoulli’s equation say in simple terms?

Along a streamline of an ideal fluid, pressure energy, kinetic energy and potential energy per unit volume add up to a constant. Where the fluid moves faster or higher, its static pressure is lower.

Should I use absolute or gauge pressure?

Either, as long as both points use the same kind. The equation only involves the difference P₁ − P₂, so the atmospheric offset cancels. A negative result is fine for gauge pressures but impossible for absolute ones.

How does a Venturi meter measure flow?

It narrows the pipe to a throat. The fluid speeds up and its pressure drops; the measured pressure difference gives the throat velocity through v₂ = √(2ΔP / (ρ(1 − β⁴))), and the flow is Q = C·A₂·v₂.

Can I use the calculator for air?

Yes, for low speeds. Air behaves as an incompressible fluid below about Mach 0.3 (roughly 100 m/s at sea level). Pick the air preset (1.204 kg/m³ at 20 °C) or enter your own density.

Why do I get “no real velocity fits”?

The energy at the other point is too small: the required ½ρv² would be negative. Usually the pressure or height at the unknown point is too high, or the pressures are mixed absolute and gauge.

Sources

Last updated:

More Physics calculators