Roof pitch is one number written four different ways. A North American framer says 6/12 (six inches of rise for every twelve inches of run), a European architect writes 26.6°, a roofing data sheet may ask for 50 %, and an old drawing may show 1 : 2. All four describe exactly the same slope, and mixing them up is a classic way to order the wrong tiles or cut rafters at the wrong angle.
This roof pitch calculator converts between all of these notations in one step. Pick the format you know, type the value, and you get the pitch as x/12, degrees, percent and 1 : n at once. If you don't know the pitch yet, choose rise and run measurements and enter the vertical height and the horizontal distance you measured: the calculator works out the slope for you.
It also gives the rafter factor (sloped length per unit of horizontal run) and the hip/valley factor, and, if you enter a horizontal run, the actual rafter length and the total rise. Those are the figures you need to cut a rafter, check a truss drawing or estimate a roof area. To turn the pitch into roof area, shingle bundles and underlayment, continue with the roofing calculator.
How to use this calculator
- Choose how you know the pitch: x/12, degrees, percent, 1 : n, or rise and run measurements.
- Type the value. For measurements, enter the rise and the run in any unit (both fields have their own unit switcher).
- Read the pitch in every notation, plus the rafter factor and the hip/valley factor.
- Optionally enter a horizontal run (half the building width on a gable, plus the overhang) to get the rafter length and the total rise.
- Check the note under the result: very shallow pitches need special coverings.
The formula
Everything starts from the slope , the rise divided by the run:
The four notations are then:
Going back: , , or .
By Pythagoras, a rafter covering a horizontal run is long; is the rafter factor (also ). A hip or valley rafter at a 90° corner between two planes of the same pitch covers a run of , so its factor per unit of common run is .
Worked example
6/12 roof. The slope is , so the angle is , the percent is 50 % and the ratio is 1 : 2. The rafter factor is : a common rafter covering a 12 ft run is 13.42 ft long (before the overhang and the ridge cut), and the hip factor is 1.5.
Measured roof. You measure a rise of 1.5 m over a run of 4 m. The slope is : that is 37.5 %, 20.56°, 4.5/12 and 1 : 2.67, and the rafter is 4.272 m long.
From degrees. A 35° roof, common in Europe, is 8.4/12 or 70.02 %.
Roof pitch chart
| Pitch | Angle | Percent | Ratio | Rafter factor | Hip factor |
|---|---|---|---|---|---|
| 1/12 | 4.76° | 8.3 % | 1 : 12 | 1.0035 | 1.4167 |
| 2/12 | 9.46° | 16.7 % | 1 : 6 | 1.0138 | 1.424 |
| 3/12 | 14.04° | 25 % | 1 : 4 | 1.0308 | 1.4361 |
| 4/12 | 18.43° | 33.3 % | 1 : 3 | 1.0541 | 1.453 |
| 5/12 | 22.62° | 41.7 % | 1 : 2.4 | 1.0833 | 1.4743 |
| 6/12 | 26.57° | 50 % | 1 : 2 | 1.118 | 1.5 |
| 7/12 | 30.26° | 58.3 % | 1 : 1.71 | 1.1577 | 1.5298 |
| 8/12 | 33.69° | 66.7 % | 1 : 1.5 | 1.2019 | 1.5635 |
| 9/12 | 36.87° | 75 % | 1 : 1.33 | 1.25 | 1.6008 |
| 10/12 | 39.81° | 83.3 % | 1 : 1.2 | 1.3017 | 1.6415 |
| 12/12 | 45° | 100 % | 1 : 1 | 1.4142 | 1.7321 |
| 18/12 | 56.31° | 150 % | 1 : 0.67 | 1.8028 | 2.0616 |
| 24/12 | 63.43° | 200 % | 1 : 0.5 | 2.2361 | 2.4495 |
Multiply a horizontal run by the rafter factor to get the sloped length, or a footprint area by the same factor to get the roof area. A 12/12 roof is 45°, 100 % and 1 : 1.
Minimum pitches by roof covering
Every covering has a minimum slope below which water can be driven back under the laps. The International Residential Code (IRC, chapter 9) sets, for example:
| Covering (IRC section) | Minimum pitch |
|---|---|
| Asphalt shingles (R905.2) | 2/12, with double underlayment up to 4/12 |
| Clay and concrete tile (R905.3) | 2½/12 |
| Slate (R905.6) | 4/12 |
| Wood shingles and shakes (R905.7, R905.8) | 3/12 |
Roofs of 3/12 or less are usually treated as low-slope and covered with membranes or standing-seam metal. In France, minimum pitches for tiles and slates depend on the product, the climate zone and the length of the slope, and are given in the DTU 40 series and the manufacturer's technical approval.
Pitch, slope and angle: which is which?
In everyday speech "pitch" and "slope" are used for the same thing, and this calculator treats them so. Strictly, some older carpentry texts define pitch as rise divided by the full span (so a 6/12 slope is a "1/4 pitch"). If a plan shows a fraction such as 1/3 or 1/4 without a "/12", it may be that older span-based pitch: double it to get rise over run. Angles are always measured from the horizontal, and percent is the rise per 100 units of run, not a percentage of 90°. For a non-roof gradient such as a ramp, a road or a line on a graph, use the slope calculator.
Frequently asked questions
How do I convert a 6/12 pitch to degrees?
Divide the rise by 12 and take the arctangent: arctan(6 ÷ 12) = arctan(0.5) = 26.57°. The same slope is 50 % and 1 : 2. The chart above gives every whole pitch from 1/12 to 12/12.
How do I measure the pitch of my roof?
Hold a level horizontally against a rafter or under the roof, mark 12 inches (or any length) along it, and measure straight up to the underside of the roof: that is the rise for that run. From the attic, measure the height from the ceiling joists to the ridge and half the building width, and enter both in the rise-and-run mode.
How do I convert degrees to percent?
Percent is 100 × tan(angle). 30° is 57.74 %, 35° is 70.02 % and 45° is 100 %. Percent is not the angle divided by 90: a 100 % pitch is 45°, not vertical.
What is the rafter factor?
It is the sloped length per unit of horizontal run, √(1 + s²), where s is rise ÷ run. Multiply the run by it to get the rafter length (before plumb and seat cuts), or a footprint area to get the roof surface. For 6/12 the factor is 1.118.
What is the most common roof pitch?
In North American houses, pitches between 4/12 and 9/12 (about 18° to 37°) are the most common, with 6/12 a frequent default. Tiled roofs in Europe are often 30° to 45°, while flat roofs have only a drainage slope of 1 to 2 %.
Sources
- International Code Council — IRC 2021, Chapter 9 Roof Assemblies (minimum slopes)
- OpenStax — Precalculus 2e, 5.4 Right Triangle Trigonometry
- National Roofing Contractors Association (NRCA)
Last updated: