Skip to content

AC BTU Calculator: What Size Air Conditioner Do You Need?

How many BTU/h your room air conditioner needs, from the room area, sun, occupants and kitchen use, in BTU and kW.

Your details

Unit system

Length × width of the space to cool. Open-plan areas count as one room.

Sun exposure

Above 8 ft (2.44 m) the capacity is scaled up in proportion to the extra volume. Lower ceilings are not reduced.

Results update as you type

Cooling capacity needed

6,000 BTU/h

Same in kilowatts
1.76 kW
Next standard split size
7,000 BTU/h
Chart value before adjustments
6,000 BTU/h
Refrigeration tons
0.5 tons
Rule of thumb 100 W/m²
2,044 W
Rule of thumb in BTU/h
6,974 BTU/h

The 100 W/m² figure is a rough French rule of thumb for an ordinary room with standard ceilings; poorly insulated, top-floor or glazed rooms can need 120–150 W/m².

Step-by-step solution
  1. Area 20.44 m² = 220 sq ft → chart: 6,000 BTU/h
  2. Total 6,000 BTU/h × 0.29307 = 1,758 W = 1.76 kW

Buy an air conditioner that is too small and it runs flat out all afternoon without ever reaching the set temperature. Buy one that is too big and it cools the air in short bursts, switches off before it has dried the room, and leaves you cold and clammy. This calculator sizes a room unit or a ductless split the simple, well-documented way: it reads the ENERGY STAR room air conditioner sizing chart for your floor area, then applies the chart's own corrections for sun, shade, occupants and cooking.

The answer is given in BTU per hour (the unit printed on most units), in kilowatts (the unit used on European labels) and in refrigeration tons, together with the next standard split size. As a cross-check, it also shows the rough 100 W/m² rule of thumb commonly quoted in France. The two methods usually land in the same size class; when they don't, it is a sign the room is unusual and deserves a closer look.

How to use this calculator

  1. Enter the floor area of the room in m² or sq ft (length × width).
  2. Choose the sun exposure: heavily shaded, normal, or very sunny (large south- or west-facing windows, top floor).
  3. Enter how many people normally use the room at the same time.
  4. Switch on kitchen if the unit will cool a cooking area.
  5. Optionally give the ceiling height when it is above 8 ft (2.44 m).
  6. Read the capacity in BTU/h and kW, and the next standard split size. The steps show every adjustment.

The formula

The chart gives a base capacity C0C_0 for the floor area band. The adjustments are then applied:

C=C0×fh×fs+600×max⁡(0, n−2)+4000 kC = C_0 \times f_h \times f_s + 600 \times \max(0,\, n-2) + 4000\,k

where fs=0.9f_s = 0.9 for a heavily shaded room, 1.11.1 for a very sunny one and 11 otherwise; nn is the number of occupants; k=1k = 1 for a kitchen. The ceiling factor fh=H/2.44 mf_h = H / 2.44\,\text{m} when the ceiling HH is higher than 8 ft (our volume-based assumption; the chart itself does not mention ceilings), otherwise 11.

Conversions: 1 BTU/h=0.29307 W1\ \text{BTU/h} = 0.29307\ \text{W}, so PkW=C×0.29307/1000P_{\text{kW}} = C \times 0.29307 / 1000; one refrigeration ton is 12,00012{,}000 BTU/h.

The French rule of thumb used as a comparison is simply P≈100 W/m2×AP \approx 100\ \text{W/m}^2 \times A.

Worked example

A 25 m² bedroom (269.1 sq ft) with a big west window and three people sleeping in it:

  • The chart band 250–300 sq ft gives 7,000 BTU/h.
  • Very sunny, +10 %: 7,700 BTU/h.
  • One person beyond two: +600 → 8,300 BTU/h, that is 2,432 W or 2.43 kW.
  • The next standard split size is 9,000 BTU/h.

The 100 W/m² rule gives 2,500 W (8,530 BTU/h): the same size class, which is reassuring.

For a 15 m² kitchen with normal sun and two people, the chart gives 6,000 BTU/h and the kitchen allowance raises it to 10,000 BTU/h (2.93 kW).

The ENERGY STAR room AC sizing chart

Area (sq ft) Area (m², approx.) Capacity (BTU/h)
100 up to 150 9.3 – 14 5,000
150 up to 250 14 – 23 6,000
250 up to 300 23 – 28 7,000
300 up to 350 28 – 32.5 8,000
350 up to 400 32.5 – 37 9,000
400 up to 450 37 – 42 10,000
450 up to 550 42 – 51 12,000
550 up to 700 51 – 65 14,000
700 up to 1,000 65 – 93 18,000
1,000 up to 1,200 93 – 111 21,000
1,200 up to 1,400 111 – 130 23,000
1,400 up to 1,500 130 – 139 24,000
1,500 up to 2,000 139 – 186 30,000
2,000 up to 2,500 186 – 232 34,000

Corrections given with the chart: reduce capacity by 10 % for a heavily shaded room, increase it by 10 % for a very sunny room, add 600 BTU/h for each regular occupant beyond two, and add 4,000 BTU/h if the unit is used in a kitchen. The metric column is a rounded conversion added for convenience.

BTU, watts and the label on a split unit

European and Moroccan labels give the cooling capacity in kW, while the model name often keeps a BTU figure: a "9000" split is about 2.6 kW, a "12000" about 3.5 kW, an "18000" about 5.3 kW and a "24000" about 7 kW. Do not confuse cooling capacity with electrical consumption: a unit with an energy efficiency ratio (EER) of 3 draws roughly one third of its cooling power from the socket. To estimate running costs, feed the electrical power into the electricity cost calculator.

When a rule of thumb is not enough

Area charts assume an ordinary room. Very large glazed areas, a flat roof in full sun, poor insulation, high ceilings, servers or many appliances all add heat. For a whole house, a shop or anything above the chart, a proper load calculation (ACCA Manual J in North America, or a room-by-room study by an installer in Europe) is the right tool. Improving insulation first, checked with the heat loss calculator, often allows a smaller and cheaper unit.

Frequently asked questions

How many BTU do I need per square foot?

It varies: about 25 to 50 BTU/h per sq ft for small rooms in the first bands of the ENERGY STAR chart, falling to about 14 BTU/h per sq ft at 2,500 sq ft. Use the chart band rather than a fixed ratio: small rooms need proportionally more.

How many m² does a 9000 BTU air conditioner cool?

According to the chart, 9,000 BTU/h suits about 350–400 sq ft (33–37 m²) in normal conditions, and less in a very sunny room or with several occupants. The 100 W/m² rule gives about 26 m², which is more cautious.

How do I convert BTU/h to watts?

Multiply by 0.29307. For example 12,000 BTU/h × 0.29307 = 3,517 W, or about 3.5 kW. To go from watts to BTU/h, multiply by 3.412.

Is a bigger air conditioner better?

No. An oversized unit cycles on and off quickly, removes less humidity and wastes energy. Choose the closest size at or just above the calculated need.

Does the calculation work for a mini split or a portable unit?

Yes for the cooling capacity. For portable single-hose units, note that their rated capacity is often optimistic in practice because they draw warm outside air into the room; choose one size up.

Sources

Last updated:

More Construction calculators

People also use