A beam that is strong enough can still be too flexible: floors that bounce, ceilings that crack and doors that jam are usually deflection problems, not strength problems. Checking how far a joist, lintel or shelf will sag is therefore one of the first things to do when choosing a section.
This beam deflection calculator covers the four textbook cases used every day on site: a beam on two supports with a load at mid-span or spread evenly, and a cantilever with a load at its free end or spread along it. Choose a material (softwood C24, steel, aluminium, concrete, or your own modulus of elasticity), give a rectangular section or a second moment of area I, and read the maximum deflection, the bending moment, the bending stress for a rectangle, the support reaction, and a comparison with a deflection limit such as L/300.
It is a quick sizing aid for pre-design and DIY projects. It does not replace a structural calculation: strength, shear, lateral buckling, load combinations, creep of timber and concrete and connections must be checked by an engineer against the Eurocodes, your national annex or your local building code.
How to use this calculator
- Choose the supports (two supports or cantilever) and the load type (uniform or point).
- Enter the span L, the clear distance between supports or the length of the cantilever.
- Enter the total load: for a uniform load, multiply the load per metre by the span (2 kN/m × 4 m = 8 kN).
- Pick the material to set E, or enter E yourself.
- Enter the width b and depth h of a rectangular section, or the second moment of area I from a steel table.
- Choose a deflection limit and read the results.
The formula
For a beam with modulus and second moment of area (rectangle: ), with a point load and the total uniform load:
| Case | Max deflection | Max moment |
|---|---|---|
| Two supports, point load at mid-span | ||
| Two supports, uniform load | ||
| Cantilever, point load at the end | ||
| Cantilever, uniform load |
The bending stress of a rectangle is . The allowable deflection is for two supports and for a cantilever.
Worked example
A C24 timber joist of 75 × 225 mm spanning 4 m carries 2 kN/m, so kN on two supports.
- cm⁴, GPa
- Deflection 8.51 mm
- Moment 4 kN·m, bending stress 6.32 MPa
- Limit L/300 = 13.33 mm: the joist passes, at about L/470
A steel IPE 300 ( cm⁴) spanning 5 m with a 10 kN point load at mid-span deflects 1.48 mm under a moment of 12.5 kN·m.
Typical deflection limits
Limits are set by codes and national annexes, so treat these as common values:
- L/300 to L/500 — instantaneous deflection of timber beams on two supports (EN 1995-1-1, Table 7.2); L/250 to L/350 for the net final deflection.
- L/250 — a frequent overall limit for steel floor beams; L/360 when brittle finishes such as plaster or tiles are supported.
- L/200 — roofs and members without sensitive finishes.
- Cantilevers — about half the ratio, i.e. 2L/300 for an L/300 target.
Timber and concrete also creep: long-term deflection under permanent load can be 1.6 to 3 times the instantaneous value, which this calculator does not include.
Why depth matters most
Because grows with the cube of the depth, a 225 mm joist is about 2.4 times stiffer than a 170 mm one of the same width, while doubling the width only doubles the stiffness. Deflection also grows with the cube or fourth power of the span: a 10 % longer span gives 33 to 46 % more sag.
Frequently asked questions
What is the formula for the deflection of a simply supported beam?
Under a uniform load w per metre it is 5wL⁴/384EI at mid-span; under a single central point load P it is PL³/48EI.
How much can a beam deflect?
Commonly L/300 for floors (12 mm on a 3.6 m span), L/360 under brittle finishes and L/200 for roofs, but the binding limit comes from your code or national annex.
What E should I use for timber?
For strength class C24 the mean modulus is 11,000 MPa (EN 338); C16 is 8,000 MPa and C30 is 12,000 MPa. Deflection checks use the mean value.
How do I get I for a steel beam?
Read Iy (strong axis) from the manufacturer’s section table, e.g. 8,356 cm⁴ for an IPE 300, and enter it with “Enter I”.
Does the calculator include the beam’s own weight?
No. Add the self-weight to the uniform load: a 75 × 225 mm C24 joist weighs about 7 kg/m, or 0.07 kN/m.
Sources
- American Wood Council — Design Aid 6: Beam Design Formulas with Shear and Moment Diagrams
- Gere & Goodno — Mechanics of Materials (Cengage), deflections of beams
- EN 1995-1-1 (Eurocode 5) — Design of timber structures, Table 7.2 deflection limits
- EN 1993-1-1 (Eurocode 3) — Design of steel structures, E = 210,000 N/mm²
- EN 338:2016 — Structural timber strength classes (C24: E0,mean = 11 kN/mm²)
Last updated: