Skip to content

Water Heating Calculator: Energy, Time and Cost

Energy, time and cost to heat water in a kettle or water heater, including melting ice and boiling.

Your details

Unit system

As liquid water: 1 L weighs about 1 kg. For ice, enter the volume of the water it was made from.

At sea level water boils at 100 °C (212 °F). Above that, the water is turned into steam first.

Kettles: 1500–3000 W. Electric water heaters: often 1200–3000 W (4500 W common in the US). Induction hob zone: 1400–3700 W.

W

Share of the power that ends up in the water. Kettle about 80–90 %, immersion heater close to 100 %, gas hob 30–50 %.

%
$

Results update as you type

Heat absorbed by the water

300.38 BTU

Heating time
2 min 56 sec
Electricity used
0.0978 kWh
Cost
$0.0196
Mass of water
2.086 lb

This brings the water to the boil without evaporating it. Each extra minute of rolling boil turns more water into steam.

Step-by-step solution
  1. m = 0.946 L × 1 kg/L = 0.946 kg
  2. Heat the liquid water: 0.946 × 4.186 × 80 K = 316.91 kJ
  3. Q = 300.377 BTU
  4. t = 316,915 J ÷ (2,000 W × 0.9) = 176.1 s

Why does a full kettle take three minutes and a hot-water tank several hours? Both obey the same physics: heating water takes 4.186 kJ per kilogram per degree, and the heater can only deliver energy as fast as its power rating allows. This water heating calculator turns a volume and two temperatures into the heat the water must absorb, then divides by the power of your appliance to give the heating time, the electricity used and its cost.

It goes beyond the simple Q=mcΔTQ = mc\Delta T: start below 0 °C and it adds the energy to warm and melt the ice; ask for more than 100 °C, or tick "boil all the water away", and it adds the latent heat of vaporization and heats the steam. A breakdown table shows how much of the energy each stage takes — melting and boiling usually dominate.

Use it for a kettle, a pan on an induction hob, a camping stove, an immersion heater, or a domestic hot-water tank (cylinder) when you want to know how long it needs to recover after a shower.

How to use this calculator

  1. Enter the amount of water in litres, millilitres, cups or gallons.
  2. Enter the starting and target temperatures. Tap water is typically 10–20 °C; a hot-water tank is usually set to 55–65 °C.
  3. If you start from ice at exactly 0 °C, or want the water fully evaporated at 100 °C, tick the matching option.
  4. Enter the power of the heater in watts and its efficiency (the share of energy that reaches the water).
  5. Optionally enter your electricity price per kWh to get the cost. Read the energy, the time and the stage-by-stage table.

The formula

With mm the mass of water (1 L ≈ 1 kg), the heat for each stage at 1 atm is:

Qice=m cice (0−T1)Qmelt=m LfQwater=m cw ΔTQ_\text{ice} = m\,c_\text{ice}\,(0 - T_1) \qquad Q_\text{melt} = m\,L_f \qquad Q_\text{water} = m\,c_w\,\Delta T
Qboil=m LvQsteam=m csteam (T2−100)Q_\text{boil} = m\,L_v \qquad Q_\text{steam} = m\,c_\text{steam}\,(T_2 - 100)

with cw=4.186c_w = 4.186 kJ/(kg·K), cice=2.09c_\text{ice} = 2.09, csteam=2.02c_\text{steam} = 2.02, Lf=334L_f = 334 kJ/kg and Lv=2256L_v = 2256 kJ/kg. Only the stages crossed between the two temperatures are added. The time and the electricity used follow from the power PP and efficiency η\eta:

t=QP ηEelec=Qη,1 kWh=3600 kJt = \frac{Q}{P\,\eta} \qquad E_\text{elec} = \frac{Q}{\eta}, \quad 1\ \text{kWh} = 3600\ \text{kJ}

Worked example

Kettle. Bring 1 L of water from 20 °C to the boil:

Q=1×4.186×80=334.88 kJQ = 1 \times 4.186 \times 80 = 334.88\ \text{kJ}

A 2000 W kettle with no losses would need 334 880/2000=167334\,880 / 2000 = 167 s. At 90 % efficiency it takes 186 s (3 minutes and 6 seconds) and draws 0.1034 kWh, about 0.021 at 0.20 per kWh.

Hot-water tank. A 200 L cylinder heated from 15 °C to 60 °C needs 37,674 kJ, that is 10.47 kWh. A 2200 W element takes about 4 hours and 45 minutes; at 0.20 per kWh a full reheat costs 2.09.

From ice to vapour. Taking 0.5 kg of ice at −10 °C all the way to steam needs 1,514.75 kJ: 10.45 + 167 + 209.3 + 1,128 kJ for the four stages. Boiling alone is 74 % of the total.

Why boiling takes so much energy

Warming liquid water from 0 to 100 °C needs 418.6 kJ per kilogram. Turning that same kilogram into steam at 100 °C needs 2256 kJ more, over five times as much, because the molecules must be pulled apart rather than just made to move faster. Melting ice is cheaper but still sizeable: 334 kJ/kg, the same as heating liquid water by 80 °C. That is why a pan left boiling uncovered wastes energy, and why ice is such an effective coolant.

Hot-water tanks and real-world losses

For an electric water heater (immersion heater or tank), nearly all of the electrical energy ends up as heat in the water, so efficiency is close to 100 % while it heats. The extra consumption comes from standby losses through the insulation, often 1–2 kWh a day for an older tank, which this calculator does not include. Kettles lose some heat to the body and the air (about 10–20 %); a pan on a gas flame loses much more. For heat pumps the "efficiency" exceeds 100 % (a coefficient of performance of 2.5–4), which you can enter as 100 % and divide the electricity by the COP.

Frequently asked questions

How much energy does it take to heat 1 litre of water by 1 °C?

About 4.19 kJ, or 1.16 Wh. Heating a litre from 20 °C to 100 °C therefore needs about 335 kJ (0.093 kWh) before losses.

How long does a 2 kW kettle take to boil 1 litre?

About 167 seconds in theory from 20 °C, and around 3 minutes in practice because some heat warms the kettle and the air. Halve the water and you roughly halve the time.

How long does a water heater take to heat up?

Divide the energy by the element power. A 200 L tank heated by 45 °C needs about 10.5 kWh, so roughly 4 h 45 min with a 2.2 kW element. Larger elements, or a partial reheat, are faster.

Does altitude change the result?

Yes. At altitude water boils below 100 °C (around 95 °C at 1500 m), so less energy is needed to reach the boil. Enter your local boiling point as the target temperature.

Why use 4.186 kJ/(kg·K) for water?

It is the textbook value at 15 °C, the temperature that defined the original calorie. Between 0 and 100 °C the true value varies by less than 1 %, so the result stays accurate for everyday heating.

Sources

Last updated:

More Physics calculators

People also use