The dew point is the temperature to which air must be cooled, at constant pressure and moisture content, for its water vapour to start condensing. It is the temperature at which dew forms on grass at dawn, a cold can “sweats” on a summer terrace and windows mist up in a bathroom. Unlike relative humidity, which swings up and down every day simply because the temperature changes, the dew point measures how much water vapour the air actually holds — which is why forecasters prefer it to describe how muggy a day feels.
This calculator works in both directions. Enter the air temperature and the relative humidity to get the dew point; or switch to Relative humidity mode and enter the temperature and the dew point to find the humidity. In both modes you also get the absolute humidity (grams of water vapour per cubic metre of air), the actual and saturation vapour pressures, the gap between temperature and dew point and a plain-language comfort rating.
It uses the Magnus formula with the coefficients published by Alduchov and Eskridge, accurate to a few tenths of a degree for air between −40 °C and 50 °C, which covers every everyday situation from a winter morning to a desert afternoon.
How to use this calculator
- Pick Dew point (you know the humidity) or Relative humidity (you know the dew point).
- Enter the air temperature in °C, °F or K, as read on a thermometer in the shade.
- Enter the relative humidity in % from a hygrometer or weather report — or the dew point in the second mode.
- Read the result, the absolute humidity and the comfort rating. Open the steps to follow the calculation.
- To find the humidity at which condensation starts on a surface, use Solve for → relative humidity with the surface temperature as the target dew point.
The formula
The saturation vapour pressure over water (Magnus form, Alduchov–Eskridge coefficients):
with in °C. From temperature and relative humidity :
The reverse calculation gives relative humidity from the dew point:
Absolute humidity treats water vapour as an ideal gas, with in pascals, J/(kg·K) and in kelvin:
Worked example
A summer evening. The air is at 25 °C with 60% relative humidity.
- = 16.7 °C
- Saturation pressure at 25 °C: 31.62 hPa; absolute humidity: 13.8 g/m³
A glass of iced drink at less than 16.7 °C will collect condensation. Reverse: at 30 °C with a dew point of 20 °C, the relative humidity is 55.1%. At 20 °C with a dew point of 0 °C, it is only 26.2%.
Relative humidity versus dew point
Relative humidity is the ratio between the water vapour present and the maximum the air could hold at its current temperature. Warm air can hold far more vapour than cold air — roughly twice as much for every 10 °C — so the same amount of moisture gives a high relative humidity on a cool morning and a low one in the afternoon. The dew point does not change when the air simply warms or cools, so it is a better measure of how much moisture there really is. A dew point of 20 °C feels sticky whether the thermometer reads 22 °C or 32 °C.
How a dew point feels
| Dew point | How summer air feels |
|---|---|
| Up to about 13 °C (55 °F) | Dry and comfortable |
| About 13–18 °C (55–65 °F) | Sticky, with muggy evenings |
| Above about 18 °C (65 °F) | Oppressive, plenty of moisture |
These bands follow the US National Weather Service’s guidance for summer weather; they are a rule of thumb rather than a standard, and people used to humid climates tolerate higher values. In winter, dew points well below 0 °C mean very dry indoor air once it is heated, which is why skin and throats dry out.
Condensation and mould in buildings
Water condenses on any surface colder than the dew point of the room air: single glazing, thermal bridges, cold corners behind wardrobes. With indoor air at 20 °C and 60% humidity, the dew point is about 12 °C, so any wall surface cooler than that will stay damp and invite mould. Ventilating to lower the humidity, or insulating so that inner surfaces stay warmer, both remove the problem — see the insulation calculator.
Frequently asked questions
How do you calculate the dew point from humidity?
Use the Magnus formula: γ = ln(RH/100) + 17.625·T/(243.04 + T), then Td = 243.04·γ/(17.625 − γ), with T in °C. A quick approximation for humid air (RH above 50%) is Td ≈ T − (100 − RH)/5.
How do you calculate relative humidity from the dew point?
Divide the vapour pressure at the dew point by the saturation vapour pressure at the air temperature: RH = 100 × e_s(Td)/e_s(T). At 30 °C with a 20 °C dew point that gives about 55%.
Can the dew point be higher than the temperature?
No. When the air cools to its dew point, it is saturated (100% relative humidity) and any further cooling makes water condense as dew, fog or cloud. The dew point is therefore always equal to or below the air temperature.
What is absolute humidity?
The mass of water vapour in a cubic metre of air, in g/m³. Air at 25 °C and 60% relative humidity holds about 13.8 g/m³; at saturation it would hold about 23 g/m³.
How accurate is this dew point calculator?
The Alduchov–Eskridge coefficients reproduce the reference saturation vapour pressure within about 0.4% between −40 and 50 °C, which translates to dew point errors of well under 0.5 °C. The accuracy of your hygrometer (often ±2 to ±5% RH) usually matters more.
Sources
- Alduchov & Eskridge (1996), Improved Magnus form approximation of saturation vapor pressure, J. Appl. Meteor. 35, 601–609
- Lawrence (2005), The relationship between relative humidity and the dewpoint temperature in moist air, BAMS 86, 225–233
- NOAA National Weather Service — What is the dew point?
Last updated: