Skip to content

Pipe Pressure Drop Calculator (Darcy–Weisbach)

Darcy–Weisbach pressure and head loss in a pipe, with the Colebrook friction factor and a pipe roughness table.

Your details

Unit system
Known quantity

Use the bore, not the nominal size: a 2" schedule 40 steel pipe is 52.5 mm (2.067 in) inside.

Results update as you type

Pressure drop ΔP

0.011 psi

Head loss h_f
0.0255 ft
Mean velocity
0.2042 ft/s
Reynolds number
3,151
Flow regime
Transitional (turbulent formula used)
Darcy friction factor f
0.043679
Relative roughness ε/D
0.0008858
Loss per 100 m
0.166 kPa/100 m

Re is between 2,300 and 4,000: the flow is unstable and the real loss can lie anywhere between the laminar and turbulent values.

Step-by-step solution
  1. v = Q / A = 0.000126 / 0.00202683 = 0.0623 m/s
  2. Re = ρ v D / μ = 998.2 × 0.0623 × 0.0508 / 0.001002 = 3,151
  3. ε/D = 0.00088583 → f = 0.043679
  4. ΔP = f (L/D) ρ v² / 2 = 0.043679 × (45.72 / 0.0508) × 998.2 × 0.0623² / 2 = 76.04 Pa
  5. h_f = ΔP / (ρ g) = 76.04 / (998.2 × 9.80665) = 0.0078 m

Every metre of pipe costs pressure. As a fluid flows, friction against the wall and inside the fluid itself turns part of its pressure energy into heat, and the pump, the fan or the water tower has to make up for it. This pressure drop calculator applies the Darcy–Weisbach equation, the standard method taught in every fluid mechanics course and used for water networks, heating loops, irrigation, compressed air and oil lines.

Enter the flow rate (or the velocity), the inner diameter, the pipe length and the material. The calculator works out the velocity, the Reynolds number, the flow regime and the Darcy friction factor, then the pressure loss in kPa, bar or psi and the equivalent head loss in metres or feet of fluid. In laminar flow the friction factor is the exact 64/Re64/Re; in turbulent flow it solves the Colebrook–White equation by iteration, or uses the explicit Swamee–Jain or Haaland approximations if you prefer to compare.

The result is the straight-pipe (major) loss. Bends, valves and fittings add minor losses on top, and a height difference adds or removes ρgΔz\rho g \Delta z; size pumps on the total.

How to use this calculator

  1. Pick the fluid: water or air at 20 °C, or Other with its density and viscosity.
  2. Choose whether you know the flow rate (L/s, L/min, m³/h, US gpm, CFM) or the mean velocity.
  3. Enter the inner diameter and the length of the pipe run.
  4. Select the material; its absolute roughness ε comes from Moody’s table. Pick Other to type ε for an old or lined pipe.
  5. Keep Colebrook–White as the friction law, or compare the explicit formulas.
  6. Read ΔP, the head loss, the loss per 100 m and the intermediate values. Solve for finds the diameter that keeps the loss under a budget, or the flow a given pressure can push.

The formula

The Darcy–Weisbach equation gives the friction loss of a full pipe:

ΔP=f LD ρv22hf=ΔPρg\Delta P = f \, \frac{L}{D} \, \frac{\rho v^2}{2} \qquad h_f = \frac{\Delta P}{\rho g}

with v=Q/(πD2/4)v = Q / (\pi D^2/4) and Re=ρvD/μRe = \rho v D / \mu. The friction factor ff depends on the regime:

laminar (Re<2300):f=64Re\text{laminar } (Re < 2300): \quad f = \frac{64}{Re}
turbulent (Colebrook–White):1f=−2log⁡10(ε/D3.7+2.51Ref)\text{turbulent (Colebrook–White)}: \quad \frac{1}{\sqrt{f}} = -2 \log_{10}\left( \frac{\varepsilon/D}{3.7} + \frac{2.51}{Re \sqrt{f}} \right)

Colebrook is implicit, so the calculator iterates until ff stops changing. The explicit approximations, accurate to within a few per cent, are:

Swamee–Jain: f=0.25[log⁡10(ε/D3.7+5.74Re0.9)]2Haaland: 1f=−1.8log⁡10[(ε/D3.7)1.11+6.9Re]\text{Swamee–Jain: } f = \frac{0.25}{\left[\log_{10}\left(\frac{\varepsilon/D}{3.7} + \frac{5.74}{Re^{0.9}}\right)\right]^2} \qquad \text{Haaland: } \frac{1}{\sqrt{f}} = -1.8 \log_{10}\left[\left(\frac{\varepsilon/D}{3.7}\right)^{1.11} + \frac{6.9}{Re}\right]

Worked example

Water in a steel pipe. 2 L/s of water at 20 °C flows through 50 m of commercial steel pipe with a 50 mm bore (ε = 0.045 mm).

  • Velocity: v=0.002/(π×0.052/4)v = 0.002 / (\pi \times 0.05^2 / 4) = 1.019 m/s
  • Reynolds number: ReRe = 50,736, turbulent; ε/D\varepsilon/D = 0.0009
  • Colebrook friction factor: ff = 0.0237
  • Pressure drop: ΔP=0.0237×(50/0.05)×998.2×1.0192/2\Delta P = 0.0237 \times (50 / 0.05) \times 998.2 \times 1.019^2 / 2 ≈ 12.27 kPa, a head loss of 1.25 m of water

The same flow in smooth PVC loses 10.84 kPa; in a 63 mm steel bore only 3.92 kPa, which shows how strongly diameter matters.

Oil in laminar flow. 0.2 L/s of oil (ρ = 870 kg/m³, μ = 50 mPa·s) in 10 m of 25 mm pipe gives Re = 177.2, so f=64/Ref = 64/Re = 0.3611 and ΔP = 10.43 kPa, matching Hagen–Poiseuille ΔP=128μLQ/(πD4)\Delta P = 128 \mu L Q / (\pi D^4).

Pipe roughness table

Absolute roughness ε of clean new pipes, from Moody’s 1944 chart (values repeated in most textbooks). Old pipes with scale or corrosion can be several times rougher.

Material ε (mm) ε (in)
Drawn tubing, copper, PVC, PE 0.0015 0.00006
Commercial steel, wrought iron 0.045 0.0018
Asphalted cast iron 0.12 0.0048
Galvanized iron 0.15 0.006
Cast iron 0.26 0.010
Concrete 0.3 – 3 0.012 – 0.12
Riveted steel 0.9 – 9 0.035 – 0.35

Roughness only matters in turbulent flow; in laminar flow the friction factor is 64/Re64/Re whatever the wall.

Major losses, minor losses and pump sizing

This calculator returns the linear (major) pressure loss of straight pipe, often quoted per 100 m to compare designs. Fittings add minor losses ΔP=Kρv2/2\Delta P = K \rho v^2/2, with KK ≈ 0.3 to 0.9 for an elbow, about 0.2 for an open gate valve and up to 10 for a globe valve. A common shortcut converts each fitting into an equivalent length of pipe and adds it to LL. For a pumping system, the total head is the sum of the friction losses, the static lift and any pressure required at the outlet. Because loss scales with roughly Q2Q^2 in turbulent flow and D−5D^{-5} at constant flow, one size up in diameter usually saves more energy over a pump’s life than it costs.

Frequently asked questions

How do you calculate pressure drop in a pipe?

Use Darcy–Weisbach: ΔP = f × (L/D) × ρv²/2. Find the velocity from the flow and the bore, compute the Reynolds number, get the friction factor (64/Re if laminar, Colebrook if turbulent), then multiply. The calculator does each step and shows the arithmetic.

What is the difference between pressure drop and head loss?

They are the same loss in different units. Head loss h = ΔP/(ρg) expresses it as a height of the flowing fluid; for water, 10 kPa ≈ 1.02 m. Pump curves are drawn in head, gauges read pressure.

What does "perte de charge linéaire" mean?

It is the French term for the linear or major pressure loss: the friction loss per unit length of straight pipe, which is what Darcy–Weisbach gives. Singular losses at elbows, valves and tees are counted separately.

Should I use Colebrook, Swamee–Jain or Haaland?

Colebrook–White is the reference for turbulent flow in commercial pipes and the Moody chart is its graph. Swamee–Jain and Haaland are explicit fits that stay within about 1–2 % of it for usual roughness and Re, handy for spreadsheets.

Does this work for air and gases?

Yes, as long as the pressure drop is small compared with the absolute pressure (below about 10 %), so that density barely changes. For long gas pipelines or high pressure ratios, compressible-flow equations are needed.

Sources

Last updated:

More Physics calculators

People also use