Wrap a thermometer in a wet cloth, let air flow over it, and it settles below the air temperature: evaporation draws heat from the bulb until the air can take no more moisture at that rate. That reading is the wet-bulb temperature. It is the lowest temperature evaporation alone can reach, which makes it central to weather observation, evaporative coolers, cooling towers, snowmaking and, increasingly, to the limits of human heat tolerance.
This wet-bulb calculator gives the value from the ordinary air (dry-bulb) temperature and the relative humidity. Choose between two methods. The Stull formula is a compact empirical fit published in 2011, accurate to about 0.3 °C on average at sea-level pressure. The psychrometric method solves the standard psychrometer equation of the World Meteorological Organization at any air pressure, so it also works at altitude.
You also get the dew point, the wet-bulb depression (how far the wet bulb sits below the air temperature) and a reading against the heat-stress thresholds from physiology research: 35 °C as the theoretical survivability limit and about 31 °C as the level where young, healthy people were measured to lose control of their core temperature.
How to use this calculator
- Choose the method: Stull for a quick sea-level value, psychrometric for any altitude or the most physically based answer.
- Enter the air temperature in °C, °F or K, read in the shade.
- Enter the relative humidity in percent.
- For the psychrometric method, enter the station pressure (what a barometer reads where you are, not the sea-level value on weather maps).
- Read the wet-bulb temperature, the comparison with the other method, the dew point and the heat-stress reading. Use Solve for → humidity to find the humidity that gives a chosen wet-bulb temperature.
The formula
Stull (2011), with in °C and in %:
Valid for 5–99 % and from −20 to 50 °C at 101.325 kPa; arctangents in radians.
Psychrometric equation (WMO-No. 8): the vapour pressure of the air satisfies
with , hPa, the enhancement factor and in hPa. The calculator finds by bisection to better than 0.001 °C.
Worked example
Stull’s check value. At 20 °C and 50 % relative humidity the Stull formula gives 13.7 °C, the value printed in the paper. The psychrometric equation at 1013.25 hPa gives 13.8 °C; at 850 hPa (about 1500 m altitude) it drops to 13.4 °C, because evaporation is faster in thinner air.
A humid heatwave. At 35 °C and 75 % humidity, Stull gives 31.1 °C, above the 31 °C critical level measured by Vecellio and colleagues. A hotter but drier day, 45 °C and 30 %, gives 29.7 °C: lower wet-bulb, though dry heat brings its own risks. At 40 °C and 50 %, the wet bulb is 30.9 °C.
Wet-bulb temperature and the limits of human heat tolerance
Our bodies cool by sweating, and sweat can only evaporate if the skin (normally about 35 °C) is warmer than the wet-bulb temperature of the air. Sherwood and Huber (2010) therefore proposed a wet-bulb temperature of 35 °C as an upper physiological limit: above it, even a resting person in the shade with unlimited water cannot shed metabolic heat.
Laboratory experiments have since shown the real limit is lower. In the PSU HEAT project, Vecellio et al. (2022) found that young, healthy adults doing light activity lost heat balance at a critical wet-bulb of about 30.5–31 °C in warm, humid conditions, and lower still in hot, dry air. Older people, people with chronic illness and anyone exercising are at risk well below these values. Health agencies use the WBGT (wet-bulb globe temperature), which adds sun and wind, for work and sport guidance; this calculator does not compute WBGT.
Using a wet-and-dry-bulb thermometer (psychrometer)
A psychrometer pairs a dry thermometer with one whose bulb is wrapped in a wet wick. Ventilate it (sling or fan), read both, and the gap between them, the wet-bulb depression, tells you how dry the air is: zero means saturated air, a gap of 10 °C means very dry air. Meteorological services used such instruments for over a century before electronic sensors. The psychrometric mode of this calculator works the same equation backwards: from temperature and humidity to the wet-bulb reading. To go from temperature and humidity to condensation risk, see the dew point calculator.
Frequently asked questions
What is the difference between wet-bulb temperature and dew point?
The dew point is the temperature at which the air would become saturated if cooled without adding moisture. The wet-bulb temperature is reached by evaporating water into the air, which adds moisture as it cools. The wet bulb always lies between the dew point and the air temperature, and all three are equal at 100 % humidity.
How accurate is the Stull formula?
Over its valid range (5–99 % humidity, −20 to 50 °C), errors range from −1 to +0.65 °C, with a mean absolute error under 0.3 °C. It assumes sea-level pressure; at altitude, the psychrometric method is more accurate.
Why is a wet-bulb temperature of 35 °C considered deadly?
Skin is about 35 °C. When the wet-bulb temperature reaches that level, sweat can no longer remove heat by evaporation, so body temperature rises regardless of rest, shade or drinking. Measurements on volunteers suggest the practical limit is lower, around 31 °C for young healthy adults.
Is wet-bulb temperature the same as the heat index or WBGT?
No. The heat index is an apparent "feels-like" temperature in the shade. WBGT combines natural wet-bulb, globe (radiant heat) and air temperatures to guide work and sport. The wet-bulb temperature is a purely thermodynamic property of the air.
Why does the result depend on air pressure?
At lower pressure, water evaporates more readily, so the wet bulb cools further for the same temperature and humidity. At 1500 m the difference is a few tenths of a degree, which is why the psychrometric method asks for station pressure.
Sources
- Stull, R. (2011). Wet-Bulb Temperature from Relative Humidity and Air Temperature. J. Appl. Meteor. Climatol. 50, 2267–2269
- WMO-No. 8 — Guide to Instruments and Methods of Observation (Vol. I, Annex 4.B: psychrometric formulae)
- Sherwood, S. C. & Huber, M. (2010). An adaptability limit to climate change due to heat stress. PNAS 107(21), 9552–9555
- Vecellio, D. J. et al. (2022). Evaluating the 35 °C wet-bulb temperature adaptability threshold for young, healthy subjects (PSU HEAT Project). J. Appl. Physiol. 132(2), 340–345
Last updated: