Viscosity measures how strongly a fluid resists flowing. For water it changes a lot with temperature: cold water at 0 °C is about six times more viscous than water close to boiling. Engineers need the right value to size pumps and pipes, compute a Reynolds number or a pressure drop; lab technicians need it to calibrate viscometers; students meet it in every fluid mechanics course.
Enter the water temperature and this calculator returns the dynamic viscosity μ (in mPa·s, which is the same number as centipoise, and in Pa·s), the kinematic viscosity ν (in mm²/s, the same number as centistokes, and in m²/s), the density used for the conversion and the imperial equivalents. A chart shows the full curve from 0 to 100 °C.
The values are not a rough fit: they are interpolated from the reference data published by NIST, computed with the international IAPWS formulations for water. The interpolation reproduces the reference values to better than 0.01 %. For comparison the calculator also shows the classic one-line Vogel equation, handy for a spreadsheet but up to about 2 % off.
How to use this calculator
- Enter the water temperature in °C, °F or K (between the freezing and boiling points at atmospheric pressure).
- Read the dynamic viscosity μ, used in shear-stress and Reynolds-number formulas with the density.
- Read the kinematic viscosity ν = μ/ρ, used directly in the Reynolds number and in viscometer readings.
- Switch the density unit if needed, and open the steps to see each conversion.
- To find the temperature that gives a target viscosity, use Solve for → Temperature.
The formula
The dynamic viscosity relates shear stress to the velocity gradient (Newton’s law of viscosity):
The kinematic viscosity divides it by the density:
Units: and .
The calculator interpolates and from NIST tables every 5 °C (cubic interpolation of ). A simple alternative is the Vogel equation, with in kelvin:
which stays within about 2.5 % between 0 and 100 °C.
Worked example
What is the viscosity of water at 20 °C?
- Dynamic viscosity: mPa·s, i.e. 1.0016 cP or about Pa·s
- Density: kg/m³
- Kinematic viscosity: mm²/s (cSt)
The Vogel equation gives 1.0017 mPa·s, very close at this temperature. Heat the same water to 60 °C and μ drops to 0.466 mPa·s (ν = 0.474 mm²/s): it flows 2.15 times more easily. At 10 °C, typical of mains water in winter, μ = 1.3059 mPa·s.
Viscosity of water vs temperature (table)
| °C | °F | μ (mPa·s = cP) | ν (mm²/s = cSt) | ρ (kg/m³) |
|---|---|---|---|---|
| 0 | 32 | 1.791 | 1.791 | 999.8 |
| 10 | 50 | 1.306 | 1.306 | 999.7 |
| 20 | 68 | 1.002 | 1.003 | 998.2 |
| 25 | 77 | 0.890 | 0.893 | 997.1 |
| 30 | 86 | 0.797 | 0.801 | 995.7 |
| 40 | 104 | 0.653 | 0.658 | 992.2 |
| 50 | 122 | 0.547 | 0.553 | 988.0 |
| 60 | 140 | 0.466 | 0.474 | 983.2 |
| 70 | 158 | 0.404 | 0.413 | 977.8 |
| 80 | 176 | 0.354 | 0.364 | 971.8 |
| 90 | 194 | 0.314 | 0.325 | 965.3 |
| 100 | 212 | 0.282 | 0.294 | 958.4 |
Values at atmospheric pressure (the 100 °C row at the boiling pressure). Pressure has almost no effect on liquid water viscosity up to several hundred bar.
Dynamic or kinematic viscosity: which one do I need?
Use the dynamic viscosity μ whenever a force or stress appears: shear stress, drag on a sphere (Stokes’ law), the Hagen–Poiseuille law for laminar pipe flow. Use the kinematic viscosity ν when only motion matters: the Reynolds number , boundary-layer thickness, or the reading of a capillary (Ubbelohde, Cannon-Fenske) viscometer, which measures ν directly. Oil and lubricant data sheets usually give ν in cSt, while water tables and physics books usually give μ.
Why does warm water flow more easily?
In a liquid, molecules are held together by hydrogen bonds that must constantly break and re-form for the layers to slide past each other. Heat gives the molecules more energy to escape these bonds, so the resistance to flow falls quickly — much faster than the density changes. Gases behave the opposite way: the viscosity of air rises with temperature because it comes from molecular collisions rather than attraction. Dissolved salt raises the viscosity of water slightly: seawater at 20 °C is about 8 % more viscous than fresh water.
Frequently asked questions
What is the viscosity of water at 20 °C?
About 1.0016 mPa·s (cP), i.e. 1.0016 × 10⁻³ Pa·s, and a kinematic viscosity of 1.0034 mm²/s (cSt). That is why 1 cP and 1 cSt are often quoted as the viscosity of water.
Is centipoise the same as mPa·s?
Yes. 1 poise = 0.1 Pa·s, so 1 centipoise = 1 mPa·s exactly. Likewise 1 centistokes = 1 mm²/s = 10⁻⁶ m²/s.
How do I convert dynamic viscosity to kinematic viscosity?
Divide by the density in consistent units: ν (m²/s) = μ (Pa·s) / ρ (kg/m³). With μ in mPa·s and ρ in g/cm³, the result comes out directly in mm²/s (cSt).
How accurate are these values?
The reference data (NIST, based on IAPWS 2008) have an uncertainty of about 1 % or better in this range, and the interpolation adds less than 0.01 %. The Vogel estimate shown for comparison can be off by up to 2–2.5 %.
Does pressure change the viscosity of water?
Only slightly. Below about 30 °C viscosity even dips a little as pressure rises, then increases; the change stays under 1 % up to roughly 100 bar, so atmospheric values are fine for ordinary piping.
Sources
- NIST Chemistry WebBook — Thermophysical properties of fluid systems (water, IAPWS-95 and IAPWS 2008)
- IAPWS R12-08 — Formulation 2008 for the viscosity of ordinary water substance
- HyperPhysics (Georgia State University) — Viscosity
Last updated: