Skip to content

Water Viscosity Calculator (0–100 °C)

Dynamic and kinematic viscosity of liquid water from 0 to 100 °C, in mPa·s, cP, Pa·s, mm²/s and cSt.

Your details

Unit system

Liquid water at atmospheric pressure, from 0 °C (32 °F) to 100 °C (212 °F).

Results update as you type

Dynamic viscosity μ

1.0016 mPa·s (cP)

Dynamic viscosity (SI)
1.0016 × 10⁻³ Pa·s
Kinematic viscosity ν
1.0034 mm²/s (cSt)
Kinematic viscosity (SI)
1.0034 × 10⁻⁶ m²/s
Density ρ
62.3162 lb/ft³
Imperial units
1.0800 × 10⁻⁵ ft²/s · 6.7304 × 10⁻⁴ lb/(ft·s)
Vogel equation estimate
1.0017 mPa·s

The quick Vogel equation differs by 0.01 % here; the main result uses the NIST/IAPWS reference data.

Step-by-step solution
  1. T = 20 °C = 293.15 K
  2. μ = 1.0016 mPa·s = 1.0016 × 10⁻³ Pa·s
  3. ρ = 998.21 kg/m³
  4. ν = μ / ρ = 1.0016 × 10⁻³ / 998.21 = 1.0034 × 10⁻⁶ m²/s = 1.0034 mm²/s
  5. Vogel: μ ≈ 2.414 × 10⁻⁵ × 10^(247.8 / (293.15 − 140)) = 1.0017 mPa·s

Viscosity measures how strongly a fluid resists flowing. For water it changes a lot with temperature: cold water at 0 °C is about six times more viscous than water close to boiling. Engineers need the right value to size pumps and pipes, compute a Reynolds number or a pressure drop; lab technicians need it to calibrate viscometers; students meet it in every fluid mechanics course.

Enter the water temperature and this calculator returns the dynamic viscosity μ (in mPa·s, which is the same number as centipoise, and in Pa·s), the kinematic viscosity ν (in mm²/s, the same number as centistokes, and in m²/s), the density used for the conversion and the imperial equivalents. A chart shows the full curve from 0 to 100 °C.

The values are not a rough fit: they are interpolated from the reference data published by NIST, computed with the international IAPWS formulations for water. The interpolation reproduces the reference values to better than 0.01 %. For comparison the calculator also shows the classic one-line Vogel equation, handy for a spreadsheet but up to about 2 % off.

How to use this calculator

  1. Enter the water temperature in °C, °F or K (between the freezing and boiling points at atmospheric pressure).
  2. Read the dynamic viscosity μ, used in shear-stress and Reynolds-number formulas with the density.
  3. Read the kinematic viscosity ν = μ/ρ, used directly in the Reynolds number vD/νvD/\nu and in viscometer readings.
  4. Switch the density unit if needed, and open the steps to see each conversion.
  5. To find the temperature that gives a target viscosity, use Solve for → Temperature.

The formula

The dynamic viscosity μ\mu relates shear stress to the velocity gradient (Newton’s law of viscosity):

τ=μdudy\tau = \mu \frac{du}{dy}

The kinematic viscosity divides it by the density:

ν=μρ\nu = \frac{\mu}{\rho}

Units: 1 mPa⋅s=1 cP=10−3 Pa⋅s1\ \text{mPa·s} = 1\ \text{cP} = 10^{-3}\ \text{Pa·s} and 1 mm2/s=1 cSt=10−6 m2/s1\ \text{mm}^2/\text{s} = 1\ \text{cSt} = 10^{-6}\ \text{m}^2/\text{s}.

The calculator interpolates μ\mu and ρ\rho from NIST tables every 5 °C (cubic interpolation of ln⁡μ\ln\mu). A simple alternative is the Vogel equation, with TT in kelvin:

μ≈2.414×10−5×10 247.8/(T−140) Pa⋅s\mu \approx 2.414 \times 10^{-5} \times 10^{\,247.8/(T - 140)}\ \text{Pa·s}

which stays within about 2.5 % between 0 and 100 °C.

Worked example

What is the viscosity of water at 20 °C?

  • Dynamic viscosity: μ=1.0016\mu = 1.0016 mPa·s, i.e. 1.0016 cP or about 1.0×10−31.0 \times 10^{-3} Pa·s
  • Density: ρ=998.21\rho = 998.21 kg/m³
  • Kinematic viscosity: ν=μ/ρ=1.0034\nu = \mu/\rho = 1.0034 mm²/s (cSt)

The Vogel equation gives 1.0017 mPa·s, very close at this temperature. Heat the same water to 60 °C and μ drops to 0.466 mPa·s (ν = 0.474 mm²/s): it flows 2.15 times more easily. At 10 °C, typical of mains water in winter, μ = 1.3059 mPa·s.

Viscosity of water vs temperature (table)

°C °F μ (mPa·s = cP) ν (mm²/s = cSt) ρ (kg/m³)
0 32 1.791 1.791 999.8
10 50 1.306 1.306 999.7
20 68 1.002 1.003 998.2
25 77 0.890 0.893 997.1
30 86 0.797 0.801 995.7
40 104 0.653 0.658 992.2
50 122 0.547 0.553 988.0
60 140 0.466 0.474 983.2
70 158 0.404 0.413 977.8
80 176 0.354 0.364 971.8
90 194 0.314 0.325 965.3
100 212 0.282 0.294 958.4

Values at atmospheric pressure (the 100 °C row at the boiling pressure). Pressure has almost no effect on liquid water viscosity up to several hundred bar.

Dynamic or kinematic viscosity: which one do I need?

Use the dynamic viscosity μ whenever a force or stress appears: shear stress, drag on a sphere (Stokes’ law), the Hagen–Poiseuille law for laminar pipe flow. Use the kinematic viscosity ν when only motion matters: the Reynolds number Re=vD/νRe = vD/\nu, boundary-layer thickness, or the reading of a capillary (Ubbelohde, Cannon-Fenske) viscometer, which measures ν directly. Oil and lubricant data sheets usually give ν in cSt, while water tables and physics books usually give μ.

Why does warm water flow more easily?

In a liquid, molecules are held together by hydrogen bonds that must constantly break and re-form for the layers to slide past each other. Heat gives the molecules more energy to escape these bonds, so the resistance to flow falls quickly — much faster than the density changes. Gases behave the opposite way: the viscosity of air rises with temperature because it comes from molecular collisions rather than attraction. Dissolved salt raises the viscosity of water slightly: seawater at 20 °C is about 8 % more viscous than fresh water.

Frequently asked questions

What is the viscosity of water at 20 °C?

About 1.0016 mPa·s (cP), i.e. 1.0016 × 10⁻³ Pa·s, and a kinematic viscosity of 1.0034 mm²/s (cSt). That is why 1 cP and 1 cSt are often quoted as the viscosity of water.

Is centipoise the same as mPa·s?

Yes. 1 poise = 0.1 Pa·s, so 1 centipoise = 1 mPa·s exactly. Likewise 1 centistokes = 1 mm²/s = 10⁻⁶ m²/s.

How do I convert dynamic viscosity to kinematic viscosity?

Divide by the density in consistent units: ν (m²/s) = μ (Pa·s) / ρ (kg/m³). With μ in mPa·s and ρ in g/cm³, the result comes out directly in mm²/s (cSt).

How accurate are these values?

The reference data (NIST, based on IAPWS 2008) have an uncertainty of about 1 % or better in this range, and the interpolation adds less than 0.01 %. The Vogel estimate shown for comparison can be off by up to 2–2.5 %.

Does pressure change the viscosity of water?

Only slightly. Below about 30 °C viscosity even dips a little as pressure rises, then increases; the change stays under 1 % up to roughly 100 bar, so atmospheric values are fine for ordinary piping.

Sources

Last updated:

More Physics calculators